期刊文献+

一种新的采用低自感串联变压器的串联混合型有源电力滤波器 被引量:2

A New Series Hybrid Active Power Filter With Small Self-inductance Series Transformer
下载PDF
导出
摘要 为降低逆变器容量和提高系统可靠性,该文提出一种新的采用低自感(或自阻抗)串联变压器的串联混合型有源电力滤波器。不同于传统结构,该混合滤波系统中的串联变压器自感很小,其标幺值仅为0.01~0.10,且串联有源滤波器不再控制为谐波电压源或基波电流源,而是控制为谐波电流源。在该方案中,逆变器和串联变压器二次侧绕组均无须承受很大的系统基波电流,而只承受一定倍数的滤波后系统谐波电流,其代价是逆变器在原来承受谐波电压的基础上叠加承受1~10%的系统基波电压。另外,该拓扑无须谐振于基波频率的LC旁路,降低了整个滤波装置的成本、损耗。仿真和实验结果表明,该新型滤波器具有良好的滤波效果。 In order to reduce inverter capacity and enhance system reliability, a new series hybrid active power filter with small self-inductance series transformer (ST) is proposed in this paper. Different from conventional scheme, the self-inductance of the ST in this filtering system is very small about 0.01-0.10 in per unit, and the series active filter is controlled as a harmonic current source instead of a harmonic voltage source or a fundamental current source. In this scheme, both the inverter and the secondary of the ST needn't endure the source fundamental current but only endures a certain times of the filtered source harmonic currents, and no LC fundamental tuned circuit is needed, so the cost and dissipation of the whole filtering system can be cut down a 10t. The excellent filtering effects of the filter are verified by both the simulation and experiment results.
出处 《中国电机工程学报》 EI CSCD 北大核心 2008年第27期56-62,共7页 Proceedings of the CSEE
基金 国家自然科学基金项目(50477047)。~~
关键词 有源电力滤波器 容量 串联变压器 自感 谐波阻抗 电压损失 功率因数损失 active power filter capacity series transformer self-inductance harmonic impedance voltage loss power factor loss