期刊文献+

大型天然气联合循环电厂噪声的综合治理 被引量:2

Noise Comprehensive Control of Large-scale Natural Gas-fired Combined Cycle Power Plant
下载PDF
导出
摘要 天然气联合循环电厂环保节能,大多建在经济发达、人口稠密的大中型城市附近,但厂界噪声和周围声环境(主要是居民敏感点)的达标却成了极其突出的问题。通过对浙江半山天然气联合循环发电工程的分析,对主厂房、余热锅炉、冷却塔等主要噪声源治理提出方案,治理工程通过竣工验收,证明取得了良好的治理效果。 Natural gas-fired combined cycle power plants protect environment and save energy. They are of large or middle populous cities which have developed economy. But reaching the state standard of bound noise and sound environment of circumference becomes an outstanding question. This paper introduces analysis and control measures of main noise sources in Hangzhou Banshan natural gas-fired combined cycle power plant. Satisfactory effect on noise control has been achieved through acceptance check of the project completion.
作者 何语平 许平
出处 《浙江电力》 2008年第1期12-14,26,共4页 Zhejiang Electric Power
关键词 天然气 联合循环电厂 噪声控制 natural gas combined cycle power plant noise control
  • 相关文献

参考文献2

  • 1奚元福 等.环境保护计算手册[M].成都:四川科学出版社,1990..
  • 2中国环境监测总站.浙江半山天然气发电工程建设项目竣工环境保护验收监测报告[R].2006.11.