期刊文献+

肥胖对男青年血流动力学运动反应影响的实验研究 被引量:4

The influence of obese on the hemodynamic responses to exercises in young men
下载PDF
导出
摘要 目的:探究肥胖对血流动力学运动反应的影响,为肥胖相关心血管疾病的运动监控提供理论支持。方法:体重正常和肥胖男青年各10名,连续采集运动前后系统血流动力学指标(BP、HR、DP、SI、CI)和指端血流动力学参数(K′、VDF、VCF、PCII、VCTI)进行分析。结果:肥胖青年男性运动前的SBP、rHR和rPCII明显高于体重正常者;运动后eSI和eCI明显低于体重正常者;运动后eK′和ePCII明显高于体重正常者。相关分析表明,Fat%与rSBP、rHR、eSI、eCI、eK′和ePCII密切相关;系统血流动力学指标和指端血流动力学指标间的偏相关分析表明,rPCII与rHR、eK′和eCI、ePCII和eCI密切相关。结论:肥胖会引发青年男性运动前后指端血流动力学改变。运动前后系统血流动力学和指端血流动力学指标间具有相关性,提示指端容积血流脉搏波参数有望成为运动心血管机能监测的新指标。 Objective:To examine the influence of obese on the hemodynamic responses to graded exercises.Method:To record and analyse the system and fingertip hemodynamic exercise responses parameters before and after graded exercises.Result:The parameters of rSBP、rHR and rPCII of obese group(OB) were significantly higher than that of normal weight group(NW) in pre-exercises stage;eSI and eCI of OR were significantly lower than that of NW,ePCII and eK' of OR were significantly higher than that of NW in post-exerxcise stage.Partial correlation analysis showed that Fat% with system and fingertip hemodynamic parameters existed significant correlations,rPCII and rHR、eK' were significantly correlated with eCI、ePCII and eCI.Conclusion:Before and affer exercise system and fingertip hemodynamic parameters of obese young men existed significant correlations.Photoplethysmographic parameters seem to be promising for exercises cardiovascular monitoring in the future.
出处 《中国康复医学杂志》 CAS CSCD 北大核心 2008年第9期824-827,共4页 Chinese Journal of Rehabilitation Medicine
基金 河北省科技厅科技支撑项目(072761890) 河北师范大学青年基金资助课题(L2005Q1)
关键词 肥胖 运动 血流动力学 光电容积描记法 obese exercises hemodynamics photoplethysmography
  • 相关文献

参考文献18

  • 1罗志昌,张松,杨益民,李旭雯.微循环容积脉搏血流特征信息的研究[J].北京生物医学工程,2001,20(2):98-101. 被引量:20
  • 2孟兆辉,白净,王苏中,崔树起.高血压病人的光电容积脉搏波的频域分析[J].北京生物医学工程,2002,21(1):1-4. 被引量:21
  • 3Chellappan K, Zahed, E, Ali M.Effects of Physical Exercise on the Photoplethysmogram Waveform [Z]. Research and Development,SCOReD 5th Student Conference, Malaysia,2007.
  • 4Aymen A, Ashraf MG, Ouda W, et al. Different Responses of Ear and Finger Pulse Oximeter Wave Form to Cold Pressor Test[J]. Anes. Analg,2001,92(66):1483-1486.
  • 5Alien J, Overbeck K, Stansby G, et al. Photoplethysmography assessments in cardiovascular disease[J].Meas Cont,2006,39:80- 83.
  • 6李刚,李尚颖,林凌,王焱,李晓霞,卢志杨.基于动态光谱的脉搏血氧测量精度分析[J].光谱学与光谱分析,2006,26(10):1821-1824. 被引量:17
  • 7Ryszard J, Marek W, Dominika P,et al. Evaluation of venous pump in upper extremities by photoplethysmography [J]. International Journal of Angiology 2005,22-25.
  • 8John Allen, Alan Murray. Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites[J].Physiol Meas, 2003,24:297-307.
  • 9Heyward VH. Advanced Fitness Assessment and Exercise Prescription[M]. Human Kinetics, 2002. 70-71.
  • 10郝兴海,徐敏,郑慧萍,高峰,崔仲奇,高文德,杨碧波.指端容积脉搏曲线法与Swan-Ganz导管法心血管功能监测的临床对照研究[J].医疗装备,2005,18(7):6-8. 被引量:7

二级参考文献114

共引文献123

同被引文献74

引证文献4

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部