人体肺功能生物电阻抗成像技术 被引量:11

Lung Functional Imaging Based on Medical Electrical Impedance Tomography
下载PDF
导出
摘要 研究的目的在于改进生物电阻抗(EIT)重建图像质量方法。首先,采用自适应多重网格法,依据后验误差的估计,基于自适应网格剖分加速线性方程组的求解,并根据多重网格算法细分相关场域,获得圆形场域的人体呼吸过程图像;然后,研究结合先验知识的图像重建算法,根据肺部组织结构及阻抗特性,采用有限元仿真软件COMSOL求解正问题,获取融合先验知识的灵敏度系数矩阵。人体肺呼吸功能实时成像结果表明,即使采用较少的网格单元,仍可获得较高精度的正问题解,具有较高的图像质量。 A new image reconstructed algorithm was presented for the medical electrical impedance tomography(EIT).First the adaptive multi-grid algorithm was employed by which the sequence of computational grids was successively refined through the posterior error and the adaptive grids refinement,the lung ventilation was imaged considering the field as circle.Then the sensitivity matrix was solved by commercial simulation software COMSOL considering the structure and resistivity of lung,the prior information was adopted to reconstruct the lung conductivity distribution.On the lung ventilation imaging system,two steps were available to reconstruct the functional respiration process image in real-time.The images indicated that a higher accuracy solution of the forward equation and the higher spatial resolution of images could be achieved.
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2008年第5期663-668,共6页 Chinese Journal of Biomedical Engineering
基金 国家自然科学基金重点项目(50337020) 国家科技支撑计划(2006BAI03A00)
关键词 生物电阻抗成像 肺功能成像 图像重建 多重网格法 先验知识 medical electrical impedance tomography(EIT) inverse problem image reconstruct lung functional imaging prior information
  • 相关文献

参考文献21

  • 1Herderson RP, Webster JG. An impedance camera for spatially specific measurements of the thorax [J]. IEEE Trans Biomed Eng, 1978, 25:250 - 254.
  • 2Benabid AL, Balme L, Persat JC, et al. Electrical impedance brain scanner: principles and preliminary results of simulation [ J ]. TIT J Life Sci, 1978, 8: 59-68.
  • 3Brown B, Seagar A. The Sheffield data collection system [J]. Clinical Physics and Physiological Measurements, 1987, 8:91 - 97.
  • 4Smit HJ. Pulmonary vascular responses to hypoxla and hyperoxia in healthy volunteers and COPD patients measured by electrical impedance tomography [J]. Chest, 2003, 123(6):1803- 1809.
  • 5Holder DS, Temple AJ. Effectiveness of the Sheffield EIT system in distinguish patients with pulmonary pathology from a series of normal subject [ A ]. In: Holder DS eds. Clinical and Physiological Applications of Electrical Impedance Tomography [M]. London : University College London Press, 1993. 277 - 298.
  • 6Boone KG, Barber DC, Brown DC. Imaging with electricity review of the European concerted action on impedance tomography [ J ]. Journal of Medical Engineering & Technology, 1997,21(6) : 201 - 232.
  • 7McArdle FJ, Brown BH, Pearse RG, et al. The effective of the skull of low-birth weight neonates on applied potential tomography imaging of centrallised resistivity changes [ J ]. Clin Phys Physiol Meas, 1988, 9 Suppl: A55 - A60.
  • 8Noordegraaf V. Validity and reproducibility of electrical impedance tomography for measurement of calf blood flow in healthy subjects [J]. Med Biol Eng Comput, 1997, 25(2): J07- 112.
  • 9McArdle FJ, Suggett AJ, Brown BH, et al. An assessment of dynamic images by applied potential tomography for monitoring pulmonary peffusion [J]. Clin Phys Physiol Meas, 1988, 9 Suppl A:91 - 97.
  • 10Brown BH. Electrical Impedance Tomography (EIT): a review [J]. Med EngTechnol, 2003, 27 (3) : 97 - 108.

同被引文献116

引证文献11

二级引证文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部