摘要
目的:对3家市售格列喹酮片体外溶出度进行比较,为质量控制、标准评价提供依据。方法:通过光纤药物溶出原位过程监测仪测定溶出曲线,实测 T_d、T_(50)等参数。结果:3家市售格列喹酮片在不同溶出条件下质量有差异,T_d、T_(50)显示溶出速度有差异。结论:光纤溶出仪可用于评价固体制剂溶出差异。
Objective:To compare the vitro dissolution of gliquidone tablets from three pharmaceutical factories. Methods : Detect dissolution curve, T50 and Td by fiber in situ dissolution tester. Result: The vitro dissolution of gliquidone tablets from A factory have wide RSD, gliquidone tablets from B and C factory dissolute faster than that of A factory. Conclusion : Fiber - optic in situ dissolution tester is suitable for evaluation of the dissolution difference.
出处
《药物分析杂志》
CAS
CSCD
北大核心
2008年第9期1506-1508,共3页
Chinese Journal of Pharmaceutical Analysis