摘要 为提高水流量标准试验装置检测大口径机械式水表示值误差的检定精度,提出一种基于动态启停双计时原理的检定方法。依据两台计时器分别记录的被检水表通流时间和工作量器进水时间,可以方便地修正示值误差并对换向系统工作特性进行监测。研究结果证实,换向气动电磁阀不对称工作特性是换向系统不确定度的主要来源,双计时法能明显提高机械类流量仪表的示值误差检定不确定度。 In order to improve the accuracy of the measurement standard system for big-inch mechanical watermeters, a new method based on the principles of flying start and stop and double-timer methods is proposed. According to separately recording the time of watermeter tested and flow into the tank by the double timer, it is easy to provide correction and monitor the performance characteristics of the changeover system. The result of the research proves that the unsymmetry of air-operated electromagnetic valve is the primary source of uncertainty . The uncertainty of the indicating errors of mechanical flowmeters could be improved effectively by the double-timer method.
出处 《计量学报》 EI CSCD 北大核心 2008年第5期407-410,共4页 Acta Metrologica Sinica
关键词 计量学 液体流量标准装置 换向器 双计时法 流量计 水表 Metrology Standard facilities for liquid flow-rate Changeover Double-timer method Flowmeters Watermeter
  • 相关文献

参考文献5

  • 1段慧明.液体流量标准装置[M].北京:中国计量出版社,2000.
  • 2JIG198-1994,速度式流量计[S].
  • 3JJG164-2000,液体流量标准装置[S].
  • 4王昌第.用液体校验流量计方法的综述[R].上海工业自动化仪表研究所,1982.
  • 5OIML R 49 - 2006, Water meters intended for the metering of cold potable water and hot water[S].

共引文献6

同被引文献26

  • 1段慧明.D_N25换向器最佳结构设计[J].计量技术,1993(7):24-26. 被引量:2
  • 2李刚,杨惠连,冉昭明.水流量标准装置设计中的若干问题[J].自动化与仪表,1993,8(1):9-11. 被引量:1
  • 3苏昌林,邱东利.远程校准技术纵览[J].中国测试技术,2006,32(3):1-6. 被引量:12
  • 4史振东,李旭,王东伟.两种换向器在液体流量标准装置中的应用[J].计量技术,2006(12):65-66. 被引量:16
  • 5Engel, Rainer. Modeling the Uncertainty in Liquid Flowmeter Cali- bration and Application-Requirement and Their Technical Realiza- tion for PTB's National Water Flow Standard[ C ]//SENSOR Con- ference 2007 Proceedings Ⅱ.
  • 6Doihara R, Shimada T, Terao Y, et al. Development of Weighing Tank System Employing Rotating Double Wing Diverter[ J]. Flow Measurement and Instrumentation, 2006,17 : 141 - 152.
  • 7Gowda V,Yeh T T, Espina P I, et al. The New NIST Water Flow Calibration Facility[ C ]//Proe of 11 th FLMEKO 2003.
  • 8Tokihiko Kobata, Momoko Kojima, Hiroaki Kajikawa. Develop- ment of remote calibration system for pressure standard [ J ]. Measurement, 2012,45 : 2482 - 2485.
  • 9Albu M, Ferrero A, Mihai F, et al. Remote calibration using mo- bile, multiagent Technology [J]. IEEE Transactions on Instru- mentation and Measurement,2005,54:24 - 30.
  • 10Amicone D, Bernieri A, Betta G, et al. On the remote calibration of electrical energy meters[ C]fjl6th IMEKO-TC4 Symposium, 2008 : 645 - 650.