摘要
地埋管换热器是地埋管地源热泵系统的核心组件,但至今其长度计算尚无一种便捷、正确又易于应用的方法。用典型气象年数据确定最热月、最冷月和地表面年平均温度。在已知建筑物设计负荷情况下,通过引入平衡温度的概念,可计算建筑物逐时负荷,再由建筑物逐时负荷和水源热泵机组性能计算出制冷与制热运行系数。最后提出了一种实用且操作性强的垂直U形地埋管换热器长度计算方法。
Geothermal Heat Exchanger is a key component in Ground-Coupled Heat Pump systems, but a length calculation method of convenient, correct and suitable for applications does not exist. In our research, Typical Meteorological Year data were used to determine the hottest month, the coldest month and annual average surface temperature. When the building load is known, the building hourly load can be obtained by adopting the concept of Equilibrium Temperature. Then, the cooling fraction and the heating fraction can be calculated. A more practical and workable calculation method of vertical U-tube heat exchanger length was proposed.
出处
《制冷学报》
CAS
CSCD
北大核心
2008年第5期28-32,共5页
Journal of Refrigeration
基金
上海市重点学科建设项目(P1401)资助~~
关键词
热工学
地埋管地源热泵系统
地埋管换热器
典型气象年
平衡温度
计算方法
Pyrology
Ground-Coupled Heat Pump system
Geothermal Heat Exchanger
Typical Meteorological Year
Equilibrium Temperature
Calculation method