摘要
对广东惠州天然气发电有限公司HM-200C1D2氢气发生器运行中的故障进行分析,采取针对性的备件更换、设备修复及系统改造等有效措施,恢复了氢气发生器安全、稳定、经济的运行。给出了合理的维护建议,为氢气发生器长久稳定运行打下了坚实基础。
The operation faults of HM- 200C1 D2 hydrogen generator in Guangdong Huizhou Gas Power Generation Corporation Limited were analyzed. The effective measures aiming the faults were adopted, which includes spare parts replacement, equipment repair, system reformation and others, so the hydrogen generator returned to safety, stable and economical operation. The rational proposal for maintenance was made which lays a solid foundation for long stable operation of hydrogen generator.
出处
《华电技术》
CAS
2008年第9期43-45,共3页
HUADIAN TECHNOLOGY
关键词
工作现状
故障分析
故障处理
维护建议
working status
fault analysis
fault handling
proposal for maintenance