Beckman Coulter HMX血细胞分析仪性能评价 被引量:2

Evaluation on performance of Beckman-Coulter HMX hematocyte analyzer
下载PDF
导出
摘要 目的在了解美国贝克曼-库尔特公司生产的HMX型(Beckman Coulter HMX)血细胞分析仪的精密度、准确度、携带污染率的同时,对该仪器白细胞分类及网织细胞计数与手工法比较的相关性及可疑报警提示观察,以评价其性能。方法选用定值指控全血连续重复测定,选取白细胞、红细胞、血小板计数及血红蛋白测定4个主要参数以评价仪器精密度及准确度;高、低值样品连续重复3次评价仪器的携带污染率。选取门诊及住院患者全血标本30例观察白细胞分类,选30例标本做网织红细胞计数的检测,仪器法与手工法比较,另外选取住院患者标本30例,对异常细胞报警提示进行分析。结果质控物测定结果CV<2.24%;携带污染率小于1.13%;仪器法与手工法比较白细胞分类P>0.05;网织红细胞计数P>0.05;报警提示P<0.05。结论美国贝克曼-库尔特公司生产的HMX型血细胞分析仪准确性、精密度均良好,携带污染率低;白细胞分类及网织红细胞计数仪器法与手工法比较相关性较好;异常细胞报警提示功能敏感度高,可作筛查检测使用。 Objective To perform a technical evaluation on performance of Beckman-Coulter HMX hematocyte analyzer in regard to its accuracy, precision and carry over rate; the correlation in leukocyte differential count and reticulocyte count between the analyzer method and manual method as well as doubtful warning. Methods Rating quality control whole blood was selected to measure four parameters (WBC, RBC,PLT and HB) successively and repetitively to evaluate the precision and aecuracy; high- and low-value serum specimens were determined for successive 3 times to investigate the carry over rate. 30 whole blood samples were collected from outpatients and inpatients for WBC diff and reticulocyte count. Besides, additional 30 whole blood samples were collected from inpatients to study the abnormal cell warning. Results The detection result of quality control specimen showed CV was below 2.24%, and the carry over rate was below 1.13%. There weren't statistical differences in leukocyte differential count and reticulocyte count between analyzer method and manual method (P〉0. 05). There was statistical significance in warning hint (P〈0.05). Conclusion Beckman-Coulter HMX hematocyte analyzer is of high precision and accuracy, low carryover rate, and sensitive abnormal cell warning hint function, closely correlative to manual method. Its favorable performance makes it an available analyzer for hematocyte monitoring and detecting.
作者 韩冬严
出处 《检验医学与临床》 CAS 2008年第20期1227-1228,1230,共3页 Laboratory Medicine and Clinic
关键词 血细胞分析仪 性能 评价 hematology analyzer performance evaluation
  • 相关文献

参考文献4

二级参考文献14

  • 1彭黎明,府伟灵,高行军.Sysmex SE-9000全自动血液分析仪性能的评价[J].临床检验杂志,2004,22(5):396-397. 被引量:10
  • 2尹朝伦.Sysmex SF-3000血液分析仪常见故障分析及解决方法[J].临床检验杂志,2004,22(6):479-480. 被引量:2
  • 3邢文理,郑文芝,李淑琳,牛晓楠,牛发良.网织红细胞参比计数法研究[J].中华医学检验杂志,1994,17(2):103-106. 被引量:12
  • 4[1]International Council for Standardization in Haematology.Guidelines for the evaluation of blood cell analyzer including those used for differential leukocyte and reticulocyte counting and cell marker application[J].Clin Lab Haematol,1994,16:157-174.
  • 5[2]Carter AB,Chavda N.Evaluation of the Sysmex SE9000 automated haematology analyzer[J].Sysmex J Int,1995,5:6-16.
  • 6Preliminary evaluation of quantitative clinical laboratory methods; Approved Guideline-Second Edition. NCCLS document EP10-A2 , vol 22 ,2002.
  • 7Protocol for evaluation of automated hematology analyzer.ICSH.Clin Lab Heamotal,1984,6:69.
  • 8Evaluation of the Linearity of Quantitative Measurement Procedures: A Statistical Approach; Approved Guideline. NCCLS document EP6-A. Vol. 23 ,2003.
  • 9Method comparison and bias estimation using patient samples, Approved Guideline-Second Edition. NCCLS document EP9-A2,2002.
  • 10Reference leukocyte differential count (Proportional) and evaluation of instrument methods, NCCLS document H20-A,vol 12,1992.

共引文献48

同被引文献12

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部