期刊文献+

基于梯度矢量流Snake模型与图割的目标边界提取 被引量:1

Contour extraction based on GVF Snake and graph cuts
下载PDF
导出
摘要 针对梯度矢量流Snake模型因力场迭代次数过大造成运行时间长的不足,结合梯度矢量流Snake模型和图割理论提出了一种新的目标边界提取方法。该方法利用图割理论先对初始轮廓进行迭代寻优,使获得的轮廓线处在目标边界的"有效逼近域"内,然后将得到的轮廓线作为Snake的初始轮廓,最后利用梯度矢量流Snake模型准确提取目标边界。实验结果表明,该方法能够快速、准确地逼近到目标边界,并具有较强的抗噪性。 Aiming at the limitations of the huge waste of time in traditional GVF Snake,a novel ' contour extraction of objects method based on GVF Snake and graph cuts is proposed.First,use graph cuts to obtain coarse contour which is in the valid approach region.Then take the contour obtained above as initialized contour of GVF Snake.Finally,GVF Snake evolves to precise target contour.Experiments show that this method can converge to target contour fast and exactly,and is robust to noise.
出处 《计算机工程与应用》 CSCD 北大核心 2008年第28期158-160,共3页 Computer Engineering and Applications
基金 陕西省自然科学基金No.2005A12 陕西师范大学研究生培养创新基金No.2008CXS025~~
关键词 梯度矢量流 SNAKE模型 图割 边界提取 Gradient Vector Flow(GVF) Snake model graph cuts contour extraction
  • 相关文献

参考文献9

二级参考文献43

  • 1王洪剑,孙志宏,彭思龙.基于GVF的骨架snake模型[J].计算机应用,2004,24(9):1-3. 被引量:3
  • 2陈雷,于明,罗永兴,周宇翔.基于小波相位保持校正GVFsnake模型的B超心脏边缘提取[J].信号处理,2004,20(6):582-585. 被引量:1
  • 3[1]G.S.Mintz,S.E.Nissen,W.D.Anderson,et al.ACC clinical expert consensus document on standards for the acquisition,measurement and reporting of intravascular ultrasound studies:a report of the American College of Cardiology task force on clinical expert consensus documents.J.Am.Coll.Cardiol.,vol.37,pp.1478-1492,2001.
  • 4[2]S.E.Nissen and P.Yock.Intravascular ultrasound:novel pathophysiological insights and current clinical applications.Circulation,vol.103,pp.604-616,2001.
  • 5[3]J.Dijkstra,G.Koning,J.C.Tuinenburg,et al.Automatic border detection in intravascular ultrasound images for quantitative measurenlents of the vessel,lumen and stent parameters.Computers in Cardiology,vol.28,pp.25-28,2001.
  • 6[4]W.Liu,J.A.Zagzebski,T.Varghese,et al.Segmentation of elastographic images using a coarse-to-fine active contour model.Ultrasound in Med.& Biol.,vol.32,pp.397-408,2006.
  • 7[5]E.Brusseau,C.L.de Korte,F.Mastik,et al,"Fully automatic luminal contour segmentation in intracoronary ultrasound imagng-a statistical approach.IEEE Trans.Med.Imag,vol.23,pp.554-566,2004.
  • 8[6]M.Kass,A.Witkin,and D.Terzopoulos.Snakes:Active contour models.Int.J.Comput.Vis.,vol.1,pp.321-331,1987.
  • 9[7]C.Xu and J.L.Prince.Snakes,shapes,and gradient vector flow.IEEE Trans.Image Processing,vol.7,pp.359-369,1998.
  • 10[8]R.F.Chang,W.J.Wu,C.C.Tseng,et al.3-D snake for US in margin evaluation for malignant breast tumor excision using Mammotome.IEEE Trans.Inf.Technol.Biomed.,vol.7,pp.197-201,2003.

共引文献10

同被引文献13

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部