基于建筑性能化设计理念内涵分析,从风险管理角度运用系统安全分析方法开展复杂建筑人员安全疏散相关问题研究。重点对建筑性能化设计中人员安全疏散判定依据之一"疏散时间"计算公式进行了改进,并利用建筑人员疏散软件以天津奥林匹克中心体育场对上述问题进行模拟验证分析。
Some problems of occupant safety evacuation were discussed using the system safety analysis methods from the angle of risk management, The main content is the modification to 'evacuation time', which is one of judging basis of occupant's safety evacuation for building performance based design. And using the advanced building occupant's evacuation software to validate and analyze above problems through the case application of Tianjin Olympic center stadium. This study can provide reference as an important technique to support the regulations and code establish for complex building occupant safety evacuation performancebased design.
出处
《消防科学与技术》
CAS
2008年第10期709-712,共4页
Fire Science and Technology
基金
中国博士后科学基金资助项目(20070420117)
关键词
安全疏散
性能化设计
奥运场馆
疏散时间
safe
tyevacuation
performance based design
Olympic venues
evacuation time