摘要
区间隧道采用自然通风的方式进行排烟在国内尚属首次。采用热烟试验方法在建成的实体隧道现场,验证了成都地铁浅埋区间隧道现有的通风竖井间距和通风面积能够满足隧道排烟的要求。烟层高度高于人体特征高度,烟气通过区间隧道最近的两个通风竖井排出,烟气蔓延区域控制在两个通风竖井之间,来自隧道内外的自然风对排烟效果的影响不大。
Nature smoke exhaust in metro's shallow-burying intersectional tunnel is the first time in China. In the paper, the author get a smoke test in Chengdu Metro's shallow burying interseetional tunnel, and validated that the existed ventilation shaft interval and area can he content with the demand of the tunnel smoke exhaust. The smoke layer level is higher than the human body height. The smoke flow exhausts from the nearest ventilation shaft, and the smoke filled zone is controlled between two ventilation shafts. The wind in and out the tunnel has small influence to exhaust effect.
出处
《消防科学与技术》
CAS
2008年第10期739-741,共3页
Fire Science and Technology
关键词
地铁
浅埋区间隧道
自然排烟
热烟试验
metro
shallow burying intersectional tunnel
nature smoke exhaust
hot smoke test