1HUANG R C,WRIGHT T M, PANJABI M M, et al. Biome ehanics of nonfusion implants[J]. Orthop Clin North Am, 2005, 36:271-280.
2SENGUPTA D K. Dynamic stabilization devices in the treatment of low back pain[J].OrthopClin North Am2004;35:43-56.
3SENEGAS J, Mechanical supplementation by non rigid fixation in degenerative intervertehral lumbar segments: the WaIlis system [J]. EurSpineJ,2002, 11 (12) : 164-169.
4WISEMAN C M, LINDSEY D P, FREDRICK A D, et aL The effect of an interspinous process implant on facet loading during extension[J]. Spine. 2005 Apt 15;30(8):903-907.
5ZUCHERMANJ F, HSUK Y, HARTJJENCA, etal. Apro spective randomized multi-center study for the treatment of lumbar spinal stenosiswith the X - STOP interspinous imp lant:12year results[J]. Eur Spine J, 2004, 13: 22-31.
6LEE J. HIDA K, SEKI T, et al. An intersp inous process distractor ( X STOP) for lumbar sp inal stenosis in elderly patients: p reliminary experiences in 10 consecutive cases[J]. J Spi hal Disord Tech, 2004, 17:72-77.
7ElF M. SCHENKE H. Thelnterspinous-U: Indications, Experi ence. and Resuhs[J]. New York: Spinal Arthroplasty Society 2005.
8KONG D S, KIM E S. EOH W. Ohe-year outcome evaluation af ter interspinous implantation for degenerative spinal stenosis with segmental instahility[J]. J Korean Med Sci2007;22(2):330-335.
9KHOUEIR P, KIM K A, WANG M Y. Classification of posterior dynamic stabilization devices[J]. Neurosurg Focus. 2007 Jan 15: 22(1):E3.
10MARIOTTIN1 A, PIERI S, GIACHI S. et al. Preliminary re suhs of a soft novel lumbar intervertebral prothesis (DIAM) in the degenerative spinal pathology[J]. Acta Neuroehir Suppl 2005, 92:129-131.
同被引文献19
1TSAI K J, MURAKAMI H, LOWERY G L, et al. Abiomechanical evaluation of the stabilization effects of an interspinous device (coflexTM)[J]. Surg Orthop Adv,2006,15(3) : 165-167.
2SHIM C S, PARK S W, LEE S H,et al. Biomechanical evaluation of an interspinous stabilizing device Locker [J].Spine(Phila Pa 1976) ,2008,33 (22) :E820-827.
3GUNZBURG R, SZPALSKI M, CALLARY S A, et al. Effect of a novel interspinous implant on lumbar spinal range of motion[J]. Eur Spine J,2009,18(5) :696-703.
4KONG D S, KIM E S, EOH W. One -year outcome evaluation after interspinous implantation for degenerative spinal stenosis with segmental instability [J]. J Korean Med Sei, 2007,22(2):330-335.
5ElF M, SCHENKE H. The Interspinous-U : Indications, Experience, and Results [J].New York: spinal Arthroplasty society, 2005,12(10):245- 249.
6SALEH S A, TAWK R, GANJU A, et al . Transforaminal lumbar interbody fusion: surgical teehmique and results in 24 patients [J]. Neurosurgery. 2004,54(2) :368-374.
7HUANG R C, WRIGHT T M, PANJABI M M, et al. Biomechanices of nonfusion implants [J]. Orthop Clin North Am, 2005,36(3) :271- 280.
8SENGUPTA D K. Dynamic stabilization devices in the treatment of low back pain[J]. Orthop Clin North Am,2004,35(1) :43-56.
9TSAI K J, MURAKAMI H, LOWERY G L,et al. Abiomechanical evaluation of the stabilization effects of an interspinous device (coflexTM)[J]. SurgOrthop Adv,2006,15(3):167- 172.
10Cheh G, Bridwell KH, Lenke LG, et al. Adjacent segment disease following lumbar/thoracolumbar fusion with pedi- cle screw instrumentation: a minimum 5-year follow-up. Spine (Phila Pa 1976), 2007, 32(20): 2253-2257.