期刊文献+

壬基酚GC-MS选择监测离子确证--皮革内APEO的检测 被引量:8

Determination of Ethoxylated Nonylphenols in Leather:Approval of Selected Ions of Nonylphenols for GC-MS Quantitative Analysis
下载PDF
导出
摘要 采用GC-MS对壬基酚标准物进行分析,结果表明,壬基酚的GC-MS总离子流图(TIC)表现为多峰,其质谱图所对应多个离子中以m/z=107,121,135,149的4种离子的丰度较高。通过对各色谱峰的单独分析发现,90%以上的壬基酚的同分异构体均对应于m/z=121,135,149这3种离子,表明壬基酚标准品的组成以α位为伯碳及叔碳的同分异构体为主。采用∑SIM(121-135-149)对壬基酚标准物进行测试,完整地保留了壬基酚全扫描峰形,提取出的总离子流∑SIM占总离子流TIC的67.1%,表明提取出的离子准确地反映了各种异构体的组成。实际样品测试表明,采用∑SIM(121-135-149)测试可有效排除杂质的干扰,而且信噪比高,确保了检测的选择性和精确度。 Nonylphenol isomers were tested with GC-MS. The Total Ion Current (TIC) chromotogrophy apprearanced multi-peaks which corresponded to more than one special mass spectrum ions. The four kinds of mass spectrum ions, i.e. 107, 121, 135, 149, have higher abundance. The analysis of mass spectrum of single peak showed that more than 90% of the isomers have the three spectrum mass ions: 121, 135 and 149. These indicated that the standard nonylphenol mixture mainly consist of isomers with α-primary o-α-tertiary carbon. The selected ion monitoring test (∑SIM, m/z=121-135-149) showed that the peak is quite similar with full scanning resuit, and the sum of SIM(121-135-149) is 67.1% percent of TIC. So it can be concluded that all of the isomers were selected monitored with ∑SIM(121-135-149) which accurately represent different nonylphenol isomers. The partical sample test with ∑SIM (121- 135- 149) showed that the interference of background signal can be effectively eliminated and a high Signal to Noise (S/N) value is achieved. The ∑SIM(121-135-149) chromatograph ensured selectivity and presion of the test method.
出处 《皮革科学与工程》 CAS 2008年第5期48-51,55,共5页 Leather Science and Engineering
基金 浙江省质量技术监督系统科研计划项目
关键词 壬基酚 气相色谱-质谱 选择离子 定量分析 nonylphenol GC-MS selected ions quantitative analysis
  • 相关文献

参考文献8

  • 1Liber K, Knuth M L, Stay F S. An integrated evaluation of the persistence and effects of 4-nonylphenol in an experimental littoral ecosystem [J]. Environmental Toxicology and Chemistry 1999, 18 :357-- 362.
  • 2Guenther K, Heinke V, Thiel B, et al. Endocrine disrupting nonylphenols 'are ubiquitous in food[J]. Environmental Science & Technology 2002, 36 : 1676-- 1680.
  • 3Penalver A, Pocurull E, Borrull F. Solid-phase microextraction coupled to high-performance liquid chromatography to determine phenolic compounds in water samples [J]. Journal of Chromatograph A 2002, 953(1--2): 79 --87.
  • 4Jahnke A, Gandrass J, Ruck W. Simultaneous determination of alkylphenol ethoxylates and their biotransformation products by liquid chromatography/electrospray ionization tandem mass spectrometry[J]. Journal of ChromatographA2004, 1035(1):115--122.
  • 5Li DH. Silyl derivatization of alkylphenols, chlorophenols, and bisphenol a for simultaneous C-C-MS determination [J]. Analytical Chemistry 2001, 73: 3089--3095.
  • 6Ding WH, Tzing SH: Analysis of nonylphenol polyethoxylates and their degradation products in river water and sewage effluent hy gas chromatography-ion trap (tandem) mass spectrometry with electron impact and chemical ionization [J]. Journal of Chromatograph A 1998, 824: 79--90.
  • 7郝瑞霞,梁鹏,赵曼,王俊安,周玉文.固相萃取-气相色谱-质谱-选择离子法检测污水中壬基酚[J].环境科学,2006,27(11):2222-2227. 被引量:23
  • 8International Organization for Standardization. ISO 18857-1: Water quality--Determination of selected atkylphenols--Part 1: Method for non-filtered samples using liquid-liquid extraction and gas chromatography with mass selective detection[S]. 2005.

二级参考文献6

共引文献22

同被引文献106

引证文献8

二级引证文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部