摘要 建立了一套高灵敏度调谐式连续波腔衰荡光谱测量系统,该系统以分布反馈式(DFB)半导体激光器作为光源,利用其电流调制及调谐的特征进行衰荡和腔损耗谱测量,系统重复测量精度约为0.65×10^(-6)。对实验中出现的标准具效应进行了实验和理论分析,证实了这种效应来自衰荡腔的外部弱反射,并通过分析找出了系统中主要的反射面源。提出了标准具效应的软、硬件消除方法,实验结果表明,软件处理中数据拟合的标准误差约为0.4×10^(-6),硬件改进后腔损耗谱振荡起伏标准差由原来的9.2068×10^(-6)减少为0.4561×10^(-6)。 Using a distributed-feedback (DFB) diode laser as light source, a high sensitivity system of continuous wave (CW) cavity ring down spectroscopy was built. With the diode laser's feature of current modulation and tuning, the ring-down transient and spectrum of cavity loss can he observed easily, and the repeated measurement error of system is about 0.65 × 10^-6. The etalonlng effects found in experiment were theoretically analyzed and experimentally researched in detail, then the external weak reflection of cavity was confirmed as the source of the effects. And the main reflection face was found through analyzing. Ways of software and hardware to eliminate the effects were put forward and testified. The results show that the fitting error of software is about 0.4 × 10^-6, and after hardware improving, the standard error of cavity loss spectrum's fluctuation decreases from 9. 2068 × 10^-6 to 0. 4561 × 10^-6.
出处 《中国激光》 EI CAS CSCD 北大核心 2008年第10期1563-1566,共4页 Chinese Journal of Lasers
关键词 光谱学 衰荡光谱 标准具效应 分布反馈激光器 弱反射 spectroscopy ring down spectroscopy etaloning effects distributed-feedback laser weak reflection
  • 相关文献

参考文献13

  • 1D. Z. Anderson, J. C. Frisch, C. S. Masser. Mirror reflectometer based on optical cavity decay time[J]. Appl. Opt., 1984, 23(8):1238-1245
  • 2龚元,李斌成.连续激光光腔衰荡法精确测量高反射率[J].中国激光,2006,33(9):1247-1250. 被引量:18
  • 3A. O'Keefe, D. A. G. Deacon. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources [J]. Rev. Sci. Instrum., 1988, 59(12):2544-2551
  • 4D. Romanini, A. A. Kachanov, N. Sadeghi et al.. CW cavity ring down spectroscopy [J].Chem. Phys. Lett. , 1997, 264: 316-322
  • 5D. Romanini, A. A. Kachanov, E. Stoeckel. Cavity ring down spectroscopy: broad band absolute absorption measurements [J].Chem. Phys. Lett., 1997, 270:546-550
  • 6P. Macko, D. Romanini, S. N. Mikhailenko et al.. High sensitivity CW cavity ring down spectroscopy of water in the region of the 1.5 μm atmospheric window [J]. J. Mol. Spectrosc. , 2004, 227:90-108
  • 7Ed H. Wahl, Bernard Fidric. Chris W. Rella et al. Applications of cavity ring down spectroscopy to high precision isotope ratio measurement of ^13C/^12C in carbon dioxide[J].Isotopes in Environmental and Health Studies, 2006, 42(1):21-35
  • 8王春梅,李炯,龚天林,陈扬骎,杨晓华.腔衰荡光谱技术测量O_2禁戒跃迁绝对吸收截面[J].光学学报,2007,27(11):2087-2090. 被引量:10
  • 9高晓明,黄伟,邓伦华,邵杰,樊宏,曹振松,袁怿谦,张为俊,龚知本.1.31μm附近水汽分子的自加宽系数、氮气加宽系数的测量[J].光学学报,2006,26(5):641-646. 被引量:8
  • 10G. Berden, R. Peeters, G. Meijer. Cavity ring-down spectroscopy: experimental schemes and applications[J]. Int. Rev. PAys. Chem. , 2000, 19(4):565-607