摘要 Pulse transit time (PTT) is used as a noninvasive and cuff-less parameter to estimate blood pressure. In this paper, we develop an algorithm to obtain PTT rapidly, which is appropriate for micro-processor and could achieve good accuracy in PTT, even in noisy measurements. The algorithm is based on finite impulse response (FIR) filter to reduce the noise and an adaptive threshold to detect the significant points of ECG and PPG. Evaluation of this method is based on the signals from our PTT-based blood pressure devices. It is shown that the method works well for PPT calculation. Pulse transit time (PTT) is used as a noninvasive and cuff-less parameter to estimate blood pressure. In this paper, we develop an algorithm to obtain PTT rapidly, which is appropriate for micro-processor and could achieve good accuracy in PTT, even in noisy measurements. The algorithm is based on finite impulse response (FIR) filter to reduce the noise and an adaptive threshold to detect the significant points of ECC and PPG. Evaluation nf this method is based on the signals from our PTT-based blood pressure devices. It is shown that the method works well for PPT calculation.
作者 张静萌
出处 《生命科学仪器》 2008年第10期28-32,共5页 Life Science Instruments
关键词 脉冲中转时间 数据处理 测量方法 脉冲技术 pulse transit time data process PPG ECG
  • 相关文献

参考文献8

  • 1[1]X.F.Teng and Y.T.Zhang,"An evaluation of a PTT-Based Method for Noninvasive and Cuff-less Estimation of Arterial Blood Pressure",Proceedings ot the 28th IEEE EMBS Annual International Conference,New York City,USA,2006,pp.6049-6051.
  • 2[2]A.Johansson,C.Ahlstrom,T.Lanne,and P.Ask,"Pulse wave transit time for monitoring respiration rate",Med Bio Eng Comput(2006)44:471-478.
  • 3[3]C.C.Y.Poon and Y.T.Zhang,"Cuif-less and noninvasive measurements of arterial blood pressure by pulse transit time",Proc.Of the 27th Ann.Cord.of IEEE-EMBC,Shanghai,China,2005,pp.5877-5880.
  • 4[4]Javier Espina,Thonlas Falck,Jens Muehlsteff,Yilin Jin,Miguel A.Adan,and Xavier Aubert,"Wearable body sensor network towards continuous cuff-less blood pressure monitoring",The BSN 2008/ISSS-MDBS 2008,Hong Kong,China,2008,PP:28-32.
  • 5[5]J.Pan and W.J.Tompkins,"A Real-Time ORS Detection Algorithm",IEEE Transactions on Biomedical Engineering,Vol.BME-32,No.3,pp.230-235.1985.
  • 6[6]J.M.Zhang.P.F.Wei,and Y.Li."A LabVIEW based mensurement system for pulse wave transit time",ITAB2008,Shenzhen,China,2008.
  • 7[7]Alan V.Oppenheim,Alan S.Willskv,and S.Hamid Nawab,"Signals and Systems (second edition)".
  • 8[8]Fei Zhang,Ying Wei,and Yong Lian,"Efficient ORS detection in wearable ECG devices for body sensor network",The BSN 2008/1SSS-MDBS 2008,Hong Kong,China,2008,pp:289-291.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部