期刊文献+

300MW机组直吹式制粉系统风量调节的研究

Reasearch on Air-rate Adjustment in Direct Pulverizing System of 300 MW Unit
下载PDF
导出
摘要 国产引进型300MW机组直吹式制粉系统运行中存在风量难以调节的问题,本文研究发现其原因是热风道阻力远大于冷风道阻力及风量测量装置选用不当,并提出了相应的改进措施.实践表明改进措施是合理的。 This paper studies the problems existing in air-rate adjustment in direct pulverizing system of 300 MW brought-in unit. It is concluded that air-rate is difficult to adjust for the reason that flow resistance in hot air-duct is larger than that in cold air-duct, and that the choice of the equipment measuring air-rate is incorrectly made. Based on the analysis, this paper presents a method for improvement. The method have proved workable in production.
出处 《上海电力学院学报》 CAS 1997年第3期40-45,共6页 Journal of Shanghai University of Electric Power
关键词 直吹式 制粉系统 风量测量 机组 锅炉 direct pulverizing system flow resistance air-rate measurement
  • 相关文献

参考文献2

二级参考文献1

  • 1(美)辛 格(Singer,J.G.)主编,严金绥等.锅炉与燃烧[M]机械工业出版社,1989.