小主动脉瓣环患者机械瓣置换术后中期疗效分析 被引量:6

Intermediate-term Results after Mechanical Valve Replacement in Patients Small Aortic Root
下载PDF
导出
摘要 目的观察小主动脉瓣环患者行心瓣膜置换术后中期疗效和心功能恢复情况,探讨小口径瓣膜的使用范围。方法1990年7月至2003年6月共对62例患者施行19号主动脉机械瓣膜置换术(19mm瓣膜组),同时选择62例同期置换21号以上机械瓣膜患者做对照(21mm瓣膜组);术后随访两组患者的临床症状、体征,心电图、超声心动图等指标,采用Kaplan-Meier分析生存曲线计算两组患者的生存率,并进行比较分析。结果19mm瓣膜组中有38例主动脉瓣区仍存在Ⅱ级以上杂音,心电图检查18例有ST段改变,术后11例仍存在胸闷、胸痛症状,术后心功能Ⅱ级33例,Ⅲ级29例;21mm瓣膜组术后心电图检查6例有ST段改变,术后3例有胸闷症状,偶尔有胸痛不适6例,术后心功能Ⅱ级48例,Ⅲ级14例,两组间比较差异有统计学意义(P=0.020)。两组患者术后左心室舒张期末内径、左心室后壁厚度、左心室重量指数、主动脉跨瓣压差等均较术前明显改善(P<0.05),左心室射血分数(LVEF)术后5年与术前比较明显提高(P<0.05),但两组间比较差异无统计学意义(P>0.05)。19mm瓣膜组术后1年、5年生存率分别为93.5%、74.2%;21mm瓣膜组术后1年、5年生存率分别为95.2%、79.0%,两组间比较差异无统计学意义(P=0.231,0.110)。结论小口径主动脉瓣置换术能取得良好的效果和中期生存率。 Objective To observe the intermediate-term outcome and heart function in patients with small aortic root,and to investigate the feasibility of small size prosthesis. Methods From July 1990 to June 2003, 62 patients underwent 19mm aortic valve prosthesis(19mm group). The results were compaired with other 62 patients receiving larger prosthesis (≥ 21 mm, 21mm group). Clinical symptoms, signs, electrocardiogram (ECG) and echocardiography (UCG) were followed-up, Kaplan-Meier survival curve was used for analysis. Results In 19mm group, there were 38 patients with ≥ Ⅱ/Ⅵ grade systolic murmur in aortic valve area, 18 patients with ECG ST segment change and 11 patients with chest pain and/or chest distress. Postoperative cardiac function showed that 33 patients with heart function New York Heart Association(NYHA) class Ⅱ and 29 patients with NYHA class Ⅲ. Postoperative ECG showed in 21mm group, 6 patients with ECG ST segment change, 3 patients with chest distress and 6 patients with occasional chest pain and there were 48 patients with NYHA class Ⅱ and 14 patients with NYHA class Ⅲ ,there was statistically difference in heart function between two groups(P=0. 020). There was a significant regression of left ventrieular end diastolic diameter (LVEDD), left ventricular wall thickness, mass index, and pressure gradients in both groups (P〈0.05), and left ventricular ejection fraction (LVEF)had a significant increase in patients 5 years after operation than that before operation(P〈0.05), and there was no statistically difference in both groups (P〉0.05). Actual survival at 1,5 years were 93. 5%,74.2% in 19mm group compared with 95.2%, 79.0% in the 21mm valve group, there were no statistically difference in both groups (P= 0. 231,0. 110). Conclusion Patients with 19mm prosthetic aortic valves can experience a satisfactory improvement and get excellent intermediate-term survival.
出处 《中国胸心血管外科临床杂志》 CAS 2008年第5期329-332,共4页 Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
关键词 心脏瓣膜 小主动脉瓣环 中期疗效 Heart valve Small aortic root Intermediate-term results
  • 相关文献

参考文献12

  • 1Ruel M, AI-Faleh H, Kulik A, et al. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventrieular dysfunction: effect on survival, freedom from heart failure, and left ventricular mass regression. J Thorac Cardiovasc Surg, 2006,131 (5) : 1036-1044.
  • 2Yoshikawa K, Fukunaga S, Arinaga K, et al. Long-term results of aortic valve replacement with a small St. Jude medical valve in Japanese patients. Ann Thorac Surg, 2008, 8,5(4) : 1303-1308.
  • 3Gonzalez-Juanetey JR, Garcia-Acuna JM, Vega Fernandez M, et al. Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: implication for the surgical management of aortic stenosis. J Thorac Cardiovasc Surg, 1996, 112(2):273-280.
  • 4Penta de Peppo A, Zeitani J, Nardi P, et al. Small "functional" size after mechanical aortic valve replacement: no risk in young to middle-age patients. Ann Thorac Surg, 2005,79(6):1915- 1920.
  • 5Christakis GT, Joyner C, Fremes SE, et al. Left ventricular mass regression early after aortic valve replacement. Ann Thorac Surg, 1996, 62(4) :1084-1089.
  • 6Hanayama N, Christakis GT, Mallidi HR, et al. Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant. Ann Thorac Surg, 2002, 73 (6): 1822-1829.
  • 7Freed DH, Tam JW, Moon MC, et al. Nineteen-millimeter prosthetic aortic valves allow normalization of left ventricular mass in elderly women. Ann Thorac Surg, 2002, 74 (6): 2022- 2025.
  • 8Kato Y, Suehiro S, Shibata T, et al. Impact of valve prosthesispatient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis. J Card Surg, 2007, 22(4):314-319.
  • 9Rao V, Jamieson WR, Ivanov J, et al. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation, 2000, 102(19 Suppl 3) :1115-1119.
  • 10Arata K, Iguro Y, Masuda H, et al. Long-term follow up in patients receiving a small aortic valve prosthesis. J Heart Valve Dis, 2002, 11(6):780-784.

同被引文献74

引证文献6

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部