摘要
从造成接地电阻值产生误差的各种因素入手,利用在检测中的部分实例,分析了造成接地电阻值误差的原因,阐述了如何最大限度地控制和减少误差的发生以提高接地电阻值的准确性,使得防雷系统的安全性能大大增加。
Starting from various factors causing the errors of earth resistance, and by using some actual examples, this paper analyzes the reasons causing the errors of the value of earth resistance, expounds how to control and reduce the errors as much as possible for increasing the accuracy of the value of earth resistance and make the security of the lightning protection system (LPS) be increased greatly.
出处
《科技情报开发与经济》
2008年第27期189-190,共2页
Sci-Tech Information Development & Economy
关键词
接地电阻
检测值
误差分析
earth resistance
detection value