研究了MAP法和电化学法对煤气洗涤废水中氨氮脱除效果,实验结果表明:对于MAP法,在pH=9.5~10,n(NH4+):n(PO4^3-):n(Mg2+)=1:1.5:1.5条件下;对于电化学法,选择投氯比为1:5,总输入电流强度在1.7~2.0A时,两种工艺均可将其氨氮含量脱除至15mg/L以下,达到国家污水综合排放标准(GB8978—1996)一级。
This paper studied the ammonia nitrogen removing effect from the coal gas washing wastewater by using MAP law and the electrification research method. The experimental results indicated: regarding the MAP, under thepH=9.5~10,n(NH4+):n(PO4^3-):n(Mg2+)=1:1.5:1.5;regarding the electrification research method, the choice throws the chlorine compared to is 1 : 5 ; total input current intensity when 1.7 - 2.0 A, two crafts may its ammonia nitrogen content removing to 15 mg/L below, which achieves the national sewage synthesis emission standard( GB8978 - 1996) first - level.
出处
《湖南有色金属》
CAS
2008年第5期51-55,共5页
Hunan Nonferrous Metals
基金
国家"十一五"科技攻关课题"有色大型冶炼企业节水技术开发"(2006BAB04B06)
关键词
煤气洗涤水
氨氮
化学沉淀
电化学法
coal gas washing wastewater
ammonia nitrogen
chemical precipitation
electrification research method