摘要
通过一起实际发生的220kV线路压变谐振案例,从理论上分析了电容式电压互感器铁磁谐振产生的原因和后果,有针对性地采取改进措施,并就加强该类设备管理和应用新技术以及预防类似缺陷发生,提出意见和建议。
Through a factual case about the ferromagnetic syntony of the 220kV line voltage transformer, this paper analyzes theoretically the causes and consequences, and takes pertinently ameliorating measure, As to how to strengthen the management of such equipment and apply new technology, and how to prevent the occurrence of similar defects, this paper also makes some comments.
出处
《安徽电气工程职业技术学院学报》
2008年第3期1-6,共6页
Journal of Anhui Electrical Engineering Professional Technique College
关键词
铁磁谐振
理论分析
消谐
ferromagnetic syntony
theories analysis
eliminate syntony