摘要
研究了裂芯式可控电抗器的不对称运行方式,指出串接中性点小电抗的必要性,推导出小电抗的选择公式和谐振条件,最后讨论了中性点小电抗的绝缘水平。
This paper studies the asymmetrical operation mode of split core type controllable reactor, points out the necessity of connecting series neutral reactor, derives the formulae for determining the neutral reactor and the resonance conditions. Finally, the insulation class of neutral reactor is discussed.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
1997年第4期6-8,共3页
High Voltage Engineering
基金
国家教委博士点基金