摘要 为实现冲击波速度的精确测量,对光学条纹相机进行了标定,得到了处于不同扫速档时狭缝上不同位置在不同时间区域的扫描速度。标定结果表明,在10ns/15mm档和5ns/15mm档时,初始时刻的扫描速度明显慢于结束时刻。而对于相机的2ns/15mm档,初始时刻的扫描速度更快。相机扫描速度在不同时间差别较大,表明随着相机的老化,采用平均扫描速度和扫速非线性进行数据处理已不适用。 In order to accurately measure the velocity of shock waves, an optic streak camera was calibrated. In the different period of time, the sweep speed of the camera was measured at different sweep grade and different position. Results of the calibration experiments obviously show that the initial sweep speed was slower than the terminal sweep speed at 10ns/15mm and 5ns/15mm grade, but the terminal sweep speed was slower at 2ns/15mm grade. The sweep speed of the camera was unequal in the different period of time. It indicated that analyzing data by average sweep speed and sweep nonlinearity was inapplicable because of the camera's aging.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2008年第4期841-844,820,共5页 Nuclear Electronics & Detection Technology
基金 国家863计划项目资助课题
关键词 光学条纹相机 标定 扫描速度 扫速非线性 optic streak camera calibration sweep speed sweep nonlinearity
  • 相关文献

参考文献10

  • 1Hicks D G, et al. Shock compression of quartz in the high-pressure fluid regime[J]. Phys Plasmas, 2005, 12(8):082702.
  • 2Bradley D K, et al. Shock compression diamond to a conducting fluid[J]. Phys Rev Lett, 2004, 93 (19) : 195506.
  • 3Ozaki N, et al. Hugooniot measurements for polyimide with laser and explosives[J]. Phys Plasmas, 2003, 10(6):2475-2479.
  • 4Batani D, et al. Equation of state data for gold in the pressure range<10 Tpa[J]. Phys Rev B, 2000, 61(14): 9287-9294.
  • 5Collins G W, et al. Equation of state measurements of hydrogen isotopes on Nova[J]. Phys Plasmas, 1998, 5(5). 1864-1869.
  • 6Koenig M, et al. Relative consistency of equations of state by laser driven shock wave[J]. Phys Rev Lett, 1995, 74(12): 2260-2263.
  • 7江少恩,李文洪,孙可煦,蒋小华,刘永刚,崔延莉,陈久森,丁永坤,郑志坚.神光Ⅱ上柱形黑腔辐射驱动冲击波[J].物理学报,2004,53(10):3424-3428. 被引量:16
  • 8傅思祖,黄秀光,吴江,王瑞荣,马民勋,何钜华,叶君健,顾援.斜入射激光驱动的冲击波在样品中传播特性的实验研究[J].物理学报,2003,52(8):1877-1881. 被引量:3
  • 9江少恩,郑志坚,李文洪,丁耀南,孙可煦,刘永刚,蒋小华.X射线辐射驱动冲击波的实验测量与分析[J].物理学报,2000,49(1):94-97. 被引量:7
  • 10刘永刚,彭晓世,汤小青.光学条纹相机扫描速度和非线性的测试[J].核电子学与探测技术,2004,24(2):218-220. 被引量:11

二级参考文献11

共引文献33

同被引文献50

  • 1郭宝平,牛憨笨.高压功率晶体管在扫描相机中的应用[J].光子学报,1996,25(10):898-901. 被引量:1
  • 2梁晶,单玉生,汤秀章,王钊,路建新.烧蚀层厚度对飞片稳定性的影响[J].原子能科学技术,2007,41(2):153-157. 被引量:2
  • 3彭晓世,李三伟,安竹,蒋小华,刘永刚.激光间接驱动冲击波实验测量[J].强激光与粒子束,2007,19(5):741-745. 被引量:8
  • 4Celliers P M, Collins G W, Silva L B Da, et al. Shock-induced transformation of liquid deuterium into a metallic fluid[J]. Phys Reds Lett, 2000, 84(24): 5564-5567.
  • 5Olson R E, Leeper R J, Nobile A, et al. Preheat effect on shock propagation in indirect-drive inertial confinement fusion ablator materials[J]. Phys Rev Lett , 2003, 91(23) : 235002.
  • 6Montgomery D S, Lerche R A, Laumann C W, et al. Evaluating the accuracy of optical-streak-camera sweep rates using uncertain data[J]. Rev Sci Instrum, 1992, 63(10) : 4322-4326.
  • 7Bell P, Griffith R, Hagans K, et al. Compact optical technique for streak camera calibration[J]. Rev Sci Instrum, 2004, 7S(10): 3930- 3933.
  • 8Ghosh S, Boni R, Jaanimagi P A. Optical and X-ray streak camera gain measurements[J]. Rev Sci Instrum, 2004, 75(10): 3956-3958.
  • 9Silbernagel C T, Torres P, Kalantar D H, A method for analyzing high resolution, time domain, streak camera calibration data[C]//Proc of SPIE. 2004, 5559: 435-442.
  • 10Bohroff N. Position measurement with a resolution and noise-limited instrument[J]. Rev Sci Instrum, 1986, 57(6) : 1152-1157.

引证文献6

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部