摘要
为建立一种快速测定食品中粗蛋白质的新型分析方法,选择小麦为样品,用硫酸一过氧化氢混合溶液为消解剂,利用微波压力程序加热技术快速消解样品,用甲醛法将NH4^+转化为H^+,以KOH为标准溶液,用恒pH滴定法进行测定。结果表明:小麦干基粗蛋白的含量在14%~17%之间,RSD1.2%~2.1%(n=6或12)。与经典方法对照测定,经F检验和t检验表明两者之间无显著性差异(置信度95%)。该法操作简单、快速,试剂用量少,空白值低,工作效率大大提高,结果令人满意。
In order to establish a rapid analysis method of determination crude protein in food, we selected wheat as samples, which were digested with sulfuric acid -- hydrogen peroxide mixture solution, using the microwave pressure procedure heating technology for rapid digestion samples, using formaldehyde method which changed NH4^+ into H^+, and KOH as the standard solution, wheat samples were determinated by constant pH titration method. The results indicated that the content of crude protein in dry wheat is 14- 17%, the relatively standard deviation is 1.2% - 2.1% (n = 6 or 12). The results compared with the classic Kjeldahl determination method showed that there was no significant differenee between them (95% confidence level) by the F-test and t-test. This method is simple, quick, less reagents consumption, low gap values and can improve the efficiency of work greatly, the result is satisfactory.
出处
《粮食储藏》
2008年第5期33-35,共3页
Grain Storage
基金
河南省教育厅自然科学研究项目资助(编号2007550008)
关键词
微波消解
恒pH滴定法
粗蛋白质
小麦
microwave digestion, constant pH titration method, protein, wheat