摘要 目的探讨不同重建相位对64排螺旋CT(64MDCT)对冠状动脉成像质量的影响。方法对56例拟诊冠心病患者行64MDCT扫描后,使用Philips独立工作站提供的冠状动脉分析软件,进行冠状动脉重建。重建的方法包括容积再现、多平面重组、最大密度投影和曲面重组等。分析不同R-R时相各支冠状动脉的显示情况。结果右冠状动脉近段、远段及左前降支、左回旋支近段的最佳时相是70%和75%,右冠状动脉中段、后降支及左回旋支远段重建的最佳时相为70%,75%和40%.结论选择回顾性心电门控最佳R-R时相重建冠状动脉可最大限度减轻心脏运动伪影,提高图像质量。 Objective To evaluate the influence of different reconstruction windows on image quality of 64 detector-rows CT coronary angiography. Methods A total of 56 patients with known or suspected coronary artery disease (CAD) were detected with retrospectively ECG-gated 64-detector-row CT coronary angiography, during a single breath hold. All data of CT scan were transmitted to the EBW workstation, where three-dimensional reconstruction methods were volume rendering ( VR), multi-planar reformation ( MPR ), maximum intensity projection(MIP) , curved planar reformation( CPR ) and other analysis software on coronal artery. The quality of.images reconstructed with different R-R phase was analyzed in terms of artifacts and visibility. Selective coronary angiography was used for reference. Results The best reconstruction time of proximal and distant segments of the right coronary artery, left anterior descending artery ( LAD ), the proximal segments of left circumflex artery (LCX) were 70% and 75%, the best reconstruction time of mid-segments of the right coronary artery,PDA and distant segments of LCX were 70% ,75% and 40%. Conclusion The optimal R-R phase of retrospectively ECG-gated reconstruction images can decrease the artifacts of cardiac motion and improve the reconstructive image quality of coronary arteries.
出处 《潍坊医学院学报》 2008年第4期293-295,I0001,共4页 Acta Academiae Medicinae Weifang
关键词 冠状动脉 体层摄影术 X线计算机 重建 图像质量 Coronary artery Tomography X-ray computed Reconstruction Image quality
  • 相关文献

参考文献8

  • 1Schoepf UJ, Becker CR, Ohnesorge BM, et al. CT of coronary artery disease[ J]. Radiology,2004,232( 1 ) : 18 - 37.
  • 2赵红,刘斌,吴兴旺,余永强,沈云,廖静敏.64层螺旋CT冠状动脉成像的心率变化及其对图像质量的影响[J].实用放射学杂志,2007,23(2):145-149. 被引量:48
  • 3Hong C, Becker CR, Huber A, et al. ECG-gated reconstructed multidetector row CT coronary angiography ; effect of varying trigger delay on image quality[ J ]. Radeology ,2001,220 ( 3 ) :712 - 717.
  • 4肖格林,黄正林,余水全,张华堂,付万红.心率及重建时相对MSCT冠状动脉造影图像质量的影响[J].华夏医学,2005,18(3):319-321. 被引量:7
  • 5Nieman K, Creasing BJ, Van Geuns R J, et al. Uesfulness of multislice computed tomography fordetedcting obstructive coronary disease [ J ]. Am J Cardionl,2002,89( 9 ) :913-918.
  • 6Roos A,Kroft LJ,Bax JJ,et al. Cardiac applications of multislice computed tomography [ J ]. British Radiol,2006,79 ( 1 ) :9 - 16.
  • 7He S,Dai SP, Chen Y, et al. Optimal ECG triggering phase to reduce motion artifact in electron beam tomography coronary artery scans[ J]. Acad Radiol,2001,8( 1 ) :48.
  • 8Kopp AF, Schroeder S, Kuettner A, et al. Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective opti-mization of the image reconstruction window [ J ]. Radiology, 2001, 221 (7) :683.

二级参考文献12

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2杨明放,王荣品,何强.16层CT冠状动脉成像技术及临床应用[J].实用放射学杂志,2005,21(9):915-918. 被引量:21
  • 3张敏,李石玲,郭智萍,张英华,王凤珍.64层螺旋CT冠状动脉血管成像技术[J].中国医学影像技术,2005,21(12):1948-1950. 被引量:24
  • 4Ennedy JW.Complications associated with cardiac catheterization and angiography[J].Cath Cardiovasc Diagn,1982,8:5-11.
  • 5Hong C, Becker CR,Huber A,et al. ECG-gated reconstructed multi-detecter row CT coronary angiography:effect of varying trigger delay on image quality[J]. Radiology,2001,220:712-717.
  • 6Nieman K,Creasing BJ,Van Geuns RJ,et al.Uesfulness of multislice computed tomography fordetedcting obstructive coronary disease[J].Am J Cardionl,2002,89:913-918.
  • 7Kopp AF, Schroder S, Kuettner A, et al.Coronary arteries:retrospectively ECG-gated multi-detecter row CT angiography with selective optimization of the imagine reconstruction window[J].Radiology,2001,221:683-688.
  • 8Hoffman MBM, Wickline SA, Lorenz CH. Quantification of in-planemotion of the coronary arteries during the cardiac cycle:Implications for acquisition window duration for MR flow quantification[J].J Magn Reson Imaging,1998,8:568-576.
  • 9Hong C,Becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT corodary angiography:effect of varying trigger delay on image quality[J].Radiology,2001,220(3):712-717.
  • 10Hoffmann MH,Shi H,Manzke R,et al.Noninvasive coronary angiography with 16-detector row CT:effect of heart rate[J].Radiology,2005,234(1):86-97.

共引文献52

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部