精密补偿器水准仪磁致误差及其测试方法 被引量:5

MAGNETIC ERROR OF PRECISE COMPENSATOR LEVEL AND ITS TEST METHOD
下载PDF
导出
摘要 分析了精密补偿器水准仪磁致误差的成因,介绍了研制的一套磁致误差检测设备以及完整的检测方法。通过大量的检测数据与数理统计,表明4测回的标准差为0.008″。该设备已为全国一等水准网复测,地震形变测量和精密工程测量等检测磁致误差100多台次。 On the basis of analyzing the cause of magnetic error of precise compensator level,it is recomended that a set of magnetic error testing equipment is developed and an integral test method is formed.Through the tests with a great deal of data and the result of mathmatic statistics,it is shown that the standard deviation of four observation sets is 0.008″.The magnetic errors of precise compensator levels are tested more than one hundred sets/times for releveling of national first class net,crustal deformation survey and precise engineering survey and so on.
出处 《地壳形变与地震》 CSCD 1997年第4期67-72,共6页 Crustal Deformation and Earthquake
关键词 精密补偿器 水准仪 磁致误差 测试法 precise compensator level,magnetic error,test.
  • 相关文献

同被引文献21

  • 1国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.29-44.
  • 2董炽,张祖胜,宋淑玲,夏淑辉,刘世荣,张晓波.磁场对Ni002水准仪影响的实验[J]地壳形变与地震,1987(03).
  • 3彭沛民.对国家标准GBl2897-91部分条款的修改建议[J].地壳形变与地震,1996,16(2):85-89.
  • 4董炽.磁场对Ni002水准仪影响的实验[J].地壳形变与地震,1987,7(3):240-46.
  • 5国家技术监督局.JJG425-2003,水准仪检定规程[S].北京:中国计量出版社,2003.
  • 6GWINSTEK.ProgrammbleAC/DCPowerSource(APS-1102)[M].2009.
  • 7国家质量技术监督局.JJG1059.1-2012测量不确定度评定与表示[S].北京:中国计量出版社,2012.
  • 8State Bureau of Tech nology Supervision. JJG 1059. 1- 2012 Evaluation and Expres- sion of Uncertainty in Measurement[S]. Beijing: Chinese Me- trology Press, 2012.
  • 9Department of Metrology, State Bureau of Technology Supervision. Guidelines for the Evaluation and Presentation of Uncertainty in Measurement[M]. Beijing: Chinese Metrology Press, 2000.
  • 10State Bureau of Technology Super vision. JJG 425-2003 Verification Regulationof Levels[S]. Beijing: Chinese Metrology Press,2003.

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部