期刊文献+

天然冷源用于超市陈列柜系统的实现与评价 被引量:1

The realization and evaluation of natural cold source used in display cabinets system
下载PDF
导出
摘要 在先前研究的基础上,提出了在寒冷季节可利用室外冷空气实现冷藏的冷风柜系统。试验研究了引入室外冷空气的陈列柜系统与传统制冷陈列柜系统的性能对比,并研究了结合引入室外冷空气和运行制冷系统两种工作模式的冷风柜系统的全年运行电能消耗情况。实验结果表明了在引入室外冷空气运行模式下冷风柜具有较好的内风幕速度分布;其柜内的温度分布均匀,并且温度波动较小,完全满足超市制冷陈列柜的性能要求;冷风柜系统结合引入室外冷空气和运行制冷系统两种工作模式,在全年运行中的总电能消耗比传统陈列柜少12%(2030kW h),较大程度地节约了系统的能耗。 Based on the previous study, this paper proposed a new display cabinets system (cold -blast cabinets system) which can utilize outdoor cool air for food chilling in cold seasons. The performance eomparison between Cold - blast cabinets system in outdoor cold air chilling mode and conventional display cabinet was drawn, and the annual power consumption of the two system was researched. The results show the cabinet in outdoor cold air chilling mode has a good jet air velocity distribution and steady temperature filed, the performance meets the demand of chilled display cabinet in supermarkets; combined with two operation modes, the power consumtion of cold - blast cabinets system is 12% less than one of conventional system.
出处 《低温与超导》 CAS CSCD 北大核心 2008年第10期56-59,共4页 Cryogenics and Superconductivity
关键词 冷风柜系统 引入环境冷空气 性能对比 能耗 Cold - blast cabinets system, Outdoor cold air chilling mode, Performance comparison, Power consumption
  • 相关文献

参考文献8

  • 1Brandon S, Field, Eric Loth. Entrainment of refrigerated air curtains down a wall[J]. Experimental Thermal and Fluid Science, 2006,30 : 175 - 184.
  • 2Faramarzi R. Comparing older and newer refrigerated display eases [ J ]. ASHRAE J. , 1999,41:45 - 49.
  • 3Faramarzi R, Woodworth - Szleper M L. Effects of low - emissivity shields on the performance and power use of refrigerated display case [ J ]. ASHRAE Transactions, 1999,105 ( 1 ) :533 - 540.
  • 4Tassou S A, Datta D. Influence of supermarket environmental parameters on the frosting and defrosting of vertical muhideck display cabinets [ J ]. ASHRAE Transaction, 1999,105 ( 1 ) :491 - 496.
  • 5Zhang H J,Wang J. Research on energy saving of the parallel unit with several compressors in the refrigerated display cabinet[J]. Fluid Machinery, 2001,33 (7) :1 -4.
  • 6中国气象年鉴编辑部.中国气象年鉴(2006)[M].2007,556-558.
  • 7陈天及,林文松,余克志.超市集中供冷风陈列柜系统的开发及研究[J].低温与超导,2008,36(2):31-35. 被引量:4
  • 8EN441 - 5. Refrigerated display cabinets: temperature test[S]. CEN, European Stand, 1996.

二级参考文献9

  • 1Boiarski Mikhail, Podchemyaev Oleg, Yudin Boris, et al. Enhancement of supermarket freezers to reduce enerconsumption and increase refrigeration capacity [ C ]. Proceedings of 20^th International Refrigeration Conference. Purdue, 1996:271-276.
  • 2Tahir A. , Bansal P. K. MEPR versus EEPR valves in open supermarket refrigerated display cabinets [ J ]. Applied Thermal Engineering,2005,25 : 191 -203.
  • 3Henderson Hugh I. , Khattar Mukesh. Measured impacts supermarket humidity level on defrost performance and refrigerating system energy, use [ J ]. ASHRAE Transactions, 1999, 43:508-517.
  • 4McQuistion F C, Parker J D, et al. Heating, ventilating, and air conditioning analysis and design[ M]. New York: McGraw - Hill, 2000, 49 - 81.
  • 5Wu L X, Zhao J N, et al. Night ventilation and active cooling coupled operation for large supermarkets in cold climates[J]. Energy and Buildings, 2006, 38:1409 - 1416.
  • 6Kirkpatrick Allan T, Elleson James S. Cold air distribution system design guide[ M]. American Society of Heat: ing, Refrigerating and Air-Conditioning Engineers Inc., 1996, 66-97.
  • 7Aziz A. The critical thickness of insulation [ J ]. Heat Transfer Engineer, 1997, 18 (2): 61-91.
  • 8Cai J P, Jrgen Risum, Claus Thybo. Quality model of foodstuff in a refrigerated display cabinet [ C ]. Proceeding of 11^th International Refrigeration and Air Conditioning Conference, Purdue, 2006, 484 - 490.
  • 9陈天及,管天,余克志.陈列柜蒸发器结霜对其风幕性能的影响[J].上海水产大学学报,2002,11(2):191-192. 被引量:14

共引文献3

同被引文献12

  • 1蔡龙俊,张华.超市空调室内设计参数与总能耗分析[J].节能技术,2006,24(6):510-514. 被引量:3
  • 2Ke-zhi Yu,Guo-liang Ding,Tian-ji Chen.A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet[J].Applied Thermal Engineering,2009,29(14-15):2904-2913.
  • 3P.Olsson,Chilled cabinet surveys.Processing and quality of foods,Chilled foods:the revolution in freshness,vol.3[M].Elsevier Applied Science Publishers,London,1990,3279 -3285.
  • 4R.Faramarzi,Comparing older and newer refrigerated display cases[J].ASHRAE Journal,1999,41:45-49.
  • 5A.Tahir,P.K.Bansal,MEPR versus EEPR valves in open supermarket refrigerated display cabinets[J].Applied Thermal Engineering,2005,25 (2-3):191-203.
  • 6Brandon S.Field,Eric Loth,Entrainment of refrigerated air curtains down a wall[J].Experimental Thermal and Fluid Science,2006,30:175-184.
  • 7L.Xu,T.Ojima.Field experiments on natural energy utilization in a residential house with a double skin facade system[J].Building and Environment,2007,42:2014-2023.
  • 8H.J.Wu,D.S.Zhu,J.Li,et al.Thermodynamic analysis of earth cooling system combined with adsorption dehumidifier for air conditioning[J].Journal of South China University of technology(Natural Science Edition),2003,31 (7):37-41.
  • 9R.W.Rite,R.R.Crawford,A parametric study of the factors governing the rate of frost accumulation on domestic refrigerator-freezer finned-tube evaporator coils,Part 2[J].ASHRAE Transactions,1991,97:438-444.
  • 10Ke-zhi Yu,Guo-liang Ding,Tian-ji Chen.Experimental investigation on a vertical display cabinet with central air supply[J].Energy Conversion and Management,2009,50 (9):2257-2265.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部