期刊文献+

PDMS氧等离子体长效活性表面处理及与Si的键合 被引量:4

Long term active surface modification of Poly(dimethylsiloxane) by O_2 plasma and the PDMS-Silicon hybrid bonding
原文传递
导出
摘要 为了实现室温、常压下聚二甲基硅氧烷(PDMS)与硅的键合,本文利用氧等离子体分别对PDMS、硅进行表面改性处理。考察了等离子体射频电源功率、处理时间、氧气流量对PDMS-硅键合强度的影响。通过优化工艺适当降低PDMS表面被氧化的程度,可使PDMS活性表面的持续时间延长至45分钟,实现了PDMS-硅在室温常压下的永久性键合。通过X-射线光电子能谱(XPS)对改性后PDMS表面化学组分变化的分析,可推断出PDMS表面Si-OH的稳定性是影响键合强度的主要因素。 In this paper the oxygen plasma treatment was introduced to the poly (dimethylsiloxane) (PDMS) and silicon surface modification by which they could be bonded with each other under the room temperature and the atmosphere pressure. The effect of surface modification parameters such as RF power, treating time, and oxygen flux on the bonding strength of the PDMS - Silicon wafer was investigated. By optimizing the surface modification process, the long term active surface of PDMS was obtained. The PDMS and silicon could be bonded with each other 45 minutes after oxygen plasma treatment. After analyzing the changes of the chemical composition in the PDMS sample by XPS, it is concluded that the stability of the Si -OH is the key factors affecting the bonding strength.
出处 《功能材料与器件学报》 CAS CSCD 北大核心 2008年第5期877-882,共6页 Journal of Functional Materials and Devices
基金 国家863计划B类项目(No.2006AA04Z367)
关键词 氧等离子体 聚二甲基硅氧烷(PDMS) 键合 XPS oxygen plasma poly (dimethylsiloxane) bonding XPS
  • 相关文献

参考文献4

二级参考文献20

  • 1杨玉昆 等.合成胶粘剂[M].北京:科技出版社,1980..
  • 2王渭源.微电子机械系统.第四届全国敏感元件与传感器学术会议论文集[M].上海,1995.193.
  • 3[1]Bernhard H.Weigl,Bardell,Ron L.Catherine R.Cabrera.Lab - on - a -chip for drug development[J].Advanced drug delivery reviews,2003,55:349 - 377.
  • 4[2]Kutchoukov,V.G.Laugere,F.vanderVlist,W.et al.Fabrication of nanofluidic devices using glass - to - glass anodic bonding [J].Sensors and actuators,2004,A (114):521-527.
  • 5[3]Berthold,A.Nicola,L.Sarro,P.M.et al.Glass - to - glass anodic bonding with standard ic technology thin films as intermediate layers[J].Sensors and actuators,2000,A (82):224- 228.
  • 6[4]David C.Duffy,J.Cooper McDonald,Olivier J.A,et al.Rapid prototyping of microfluidic systems in poly (dimethylsiloxane) [J].Anal.Chem,1998,70:4974 - 4984.
  • 7[5]Carlo S.Effenhauser,Gerard J.M.Bruin,Aran Paulus,et al.Integrated capillary electrophoresis on flexible Silicone microdevices:analysis of DNA restriction fragments and detection of single DNA molecules on Microchips[J].Anal.Chem,1997,69:3451-3457.
  • 8[6]Andrew M Christensen,David A Chang- Yen,Bruce K Gale.Characterization of interconnects used in PDMS Microfluidic systems[J].Micromech.Microeng,2005,15:928-934.
  • 9[7]Kazuo Hosokawa,Kotaro Hanada,Ryutaro Macda.A Polydimethylsiloxane (PDMS) deformable diffraction grating for monitoring of local pressure in Microfluidic devices[J].Micromech.Microeng,2002,12:1-6.
  • 10[11]Seung- Woo Choi,Woo- Beom Choi,Yun- Hi Lee,et al.Effect of Oxygen Plasma Treatment on Anodic Bonding[J].Journal of the Korean Physical Society,2001,38:207-209.

共引文献36

同被引文献32

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部