数字冠脉造影与多排螺旋CT冠脉成像辐射剂量对比

Radiation Dose Comparison for MSCT Coronary Angiography and Conventional Coronary Angiography
下载PDF
导出
摘要 随着多排螺旋CT技术的发展,CT冠脉成像在临床上的应用日益广泛。该成像技术与传统数字冠脉造影在辐射剂量方面的异同也愈加受到关注。本文主要介绍两种成像技术在辐射剂量测量方面的异同及其两种技术所致辐射剂量的差别。 With the development of MSCT, the use of CT Coronary Angiography (CTA) has increased rapidly. More and more attention has been paid on the radiation doses from CTA and conventional Coronary Angiography (CA) . This paper mainly introduces the methods for measuring the radiation dose from CT and CA and comparison of radiation doses from CTA and CA.
出处 《中国医疗设备》 2008年第10期141-143,119,共4页 China Medical Devices
基金 国家自然科学基金资助项目(30870751)
关键词 冠脉造影 多排螺旋CT冠脉成像 辐射剂量 conventional coronary angiography MSCT coronary angiography radiation dose
  • 相关文献

参考文献15

  • 1[1]Brenner DJ,Hall,EJ.Computed Tomography--An Increasing Source of Radiation Exposure[J].N Eng J Med.2007 Nov 29:357(22):2277-84.
  • 2[2]ICR.P.ICRP Publication 85,Avoidance of Radiation Injuries from Medical Intervention Procedures[M].Oxford:Pergamon Press.2000.
  • 3[3]ICRP.ICRP Publication 73,Radiological Protection and Safety in Medicine[M].Oxford:Pergamon Press,1996.
  • 4[4]International Electrotechnical Commission (IEC).IEC 60601-2-43,Medical electrical equipment Part 2-43:Particular requirements for the safety of X-ray equipment for interventional procedures[S].Geneva:IEC,2000.
  • 5[6]International Electrotechnical Commission (IEC).IEC 61223-3-5,Evaluation and routine testing in medical imaging departments:Part 3-5:Acceptance tests-imaging performance of computed tomography X-ray equipment[S].Geneva:IEC,2004.
  • 6[7]ICR.P.ICR.P Publication 60,1990 Recommendations of the International Commission on Radiological Protection[M].Oxford:Pergamon Press,1991.
  • 7[8]Zankl M,Panzer W,Drexler G.The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods.Part Ⅵ:Organ doses from computed tomographic examinations.GSF-Bericht 30/91.Neuherberg,1991.
  • 8[9]Hart D,Jones DG and Wall BF.Norrmlised organ doses for medical x-ray examinations calculated using Monte Carlo techniques,NRPB-SR262[M].Chilton:NRPB,1996.
  • 9[10]CEC.Quality criteria for computed tomography,European guidelines[M].EUR 16262.Luxembourg:Commission of the European Communities,1999.
  • 10[11]Coles DR,Smail MA,Negus IS,et al.Comparison of Radiation Doses From Multislice Computed Tomography Coronary Angiography and Conventional Diagnostic Angiography[J].J.Am.Coll.Cardiol.2006;47;1840-1845.

二级参考文献20

  • 1郑钧正.加强医疗照射防护的重点工作[J].中华放射医学与防护杂志,2005,25(2):105-106. 被引量:44
  • 2郑钧正.电离辐射量与单位的演进[J].中国辐射卫生,2006,15(1):87-89. 被引量:4
  • 3郑钧正.放射诊断的医疗照射指导水平[J].中国辐射卫生,2006,15(1):128-131. 被引量:17
  • 4白玫,刘彬,郑钧正.心脏介入患者受照剂量研究[J].介入放射学杂志,2007,16(4):222-225. 被引量:14
  • 5中华人民共和国国家职业卫生标准.GBZ/T 146-2002,医疗照射放射防护名词术语[S].北京:法律出版社,2002.
  • 6International Electrotechnical Commission(IEC). IEC 60601-2-43, Medical electrical equipment Part 2-43 : Particular requirements for the safety of X-ray equipment for interventional procedures[S].Geneva : IEC, 2000.
  • 7中华人民共和国国家标准.GB9706.23-2005,医用电气设备第2-43部分:介入操作X射线设备安全专用要求[S].北京:中国标准出版社,2005.
  • 8Servomaa A and Tapiovaara M. Organ dose calculation in medical X ray examinations by the program PCXMC [J]. Radiation Protection Dosimetry, 1998,80(1-3) :213-219.
  • 9Hart D, Jones DG and Wall BF. Normalised organ doses for medical x-ray examinations calculated using Monte Carlo techniques, NRPB-SR262 [M]. Chilton: NRPB, 1996.
  • 10ICRP. ICRP Publication 60,1990 Recommendations of the international commission on radiological protection[M]. Oxford:Pergamon Press, 1991.

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部