摘要
针对煤中氟氯测定中碰到的具体问题,通过比较现行国标中基于电位分析法测定氟氯的算法,引入了较为严谨和苛刻的算法。这在煤质分析仪器自动化程度不断提高、人工参与计算日渐减少的今天,对降低煤中氟氯测定的误差,有一定的现实意义。
According to the problems in determination of fluorine and chlorine in coal, this paper introduces more precise and rigorous algorithms compared with the national standard. As the development of coal analytical instruments in automatization, the manual calculation reduces day by day. So we can brings these algorithms to reduce the error in determination of fluorine and chlorine in coal, which has realistic significances.
出处
《中国仪器仪表》
2008年第10期81-83,共3页
China Instrumentation
关键词
氟氯
电位分析法
Nernst方程
二阶微商
Fluorine and chlorine
Potentiometric analysis
Nemst equation
Second derivative