摘要
以热力学理论为基础,讨论了压缩空气的压力露点和常压露点换算方法,并给出了可靠准确的具体计算方程,可用于-100~90℃范围内的压缩空气露点温度计算,十分便于工程使用。
Based on the theory of thermodynamics, the conversion of the atmospheric dew-point temperature and the dew-point temperature under ordinary pressure is analyzed for compressed air and a set of accurate formula are provided. The conversion range is from - 100 to 90℃ for dew - points.
出处
《压缩机技术》
2008年第5期7-8,35,共3页
Compressor Technology
关键词
湿空气
压缩空气
露点温度
压力
换算
wet air
compressed air
dew-point temperature
pressure
conversion