摘要 为了研究射频对电火工品的影响,利用传导方法分别测定了三种不同的桥丝式电火工品试样的敏感频率,然后在敏感频率条件下根据升降法对试样的射频感度进行了测定和计算。对三种各30发电火工品进行了敏感频率探测试验,确定射频敏感频率均为0.4 GHz;在敏感频率条件下,利用升降法对三种各30发电火工品的射频感度进行了测试,射频感度随桥丝电阻增加而降低,计算得到50%发火功率分别为2.818 W、0.428 W和0.897 W。 The effect of radiofrequeney on three different hot-bridge electric explosive devices was studied by experiment and calculation. The sensitive frequency were measured using conduction method, and the radiofrequeney sensitivity was tested and calculated in the condition of sensitive frequency based on the up-down method. The sensitive frequencies are 0. 4 GHz through detection test of 30 samples for each electric explosive device; the fire powers are 2. 818 W,0. 428 W and 0. 897 W at 50% fire/no fire through radiofrequency sensitivity test of 30 samples for each electric explosive device,and the radiofrequeney sensitivity decreases along with the increase of electric resistance of hot-bridge.
出处 《含能材料》 EI CAS CSCD 2008年第5期547-549,552,共4页 Chinese Journal of Energetic Materials
关键词 军事化学 桥丝式电火工品 射频 感度 升降法 military chemistry hot-bridge electric explosive deviee radiofrequeney sensitivity up-down method
  • 相关文献

参考文献6

  • 1Koucherng Roger Lee,John E Bennett. New method for assessing EED susceptibility to electromagnetic radiation [ C ]//IEEE Transaction on Eleetromagnetie Compatibility. Dept. of eleetr. & Comput. Eng. , Clemson Univ. , SC, USA, 1991, 33(4): 328 -333.
  • 2Willie R C Bogan. Comparison of EMP and Hero programs [ R]. AD-A203924,1992.
  • 3马宏萱,杨洁,刘天新.射频对桥丝式电火工品性能的影响[J].火工品,2003(3):15-17. 被引量:9
  • 4陈明华,高敏,卢斌,战志波.射频电流对桥丝式电雷管安全性与可靠性影响数值计算[J].火工品,2007(4):22-25. 被引量:4
  • 5CJB736,2-89.中华人民共和国国家军用标准.火工品试验方法-电火工品射频感度测定[S].
  • 6GJB 377-87.中华人民共和国国家军用标准.感度试验用升降法[S].

二级参考文献3

  • 1Kouchemg Roger Lee, John E. Bennett. New method for assessing EED susceptibility to electromagnetic radiation[C] //IEEE Transaction on Electromagnetic Compatibility. USA:Dept.of Elector & Comput.Eng,Clemson unive.,SC, 1991:328-333.
  • 2Willie R. C. Bogan: Comparison of EMP and hero programs[R]. AD-A203924, 1992.
  • 3马宏萱,杨洁,刘天新.射频对桥丝式电火工品性能的影响[J].火工品,2003(3):15-17. 被引量:9

共引文献11

同被引文献21

  • 1李锦荣.电火工品射频感度试验[J].兵工学报,1996,17(1):93-96. 被引量:4
  • 2易建政,檀朝彬,蔡俊峰.火箭弹电点火系统抗电磁危害加固技术研究[J].装备环境工程,2006,3(4):52-54. 被引量:4
  • 3Perez R.Handbook of electromagnetic compatibility[M].New York:Academic Press,1995:75-95.
  • 4Smith A A.Coupling of external electromagnetic fields to transmission lines[M].New York:John Willey & Sons Inc,1977:20-46.
  • 5Agrawal A K,Price H I,Gurbaxani S H.Transient response of multiconductor transmission lines excited by a nonuniform electromagnetic field[J].IEEE Trans Electromagn Compat,1980,EMC-22(2):119-129.
  • 6Howson D P, Exeell P S, Butcher G H. Ignition of flammable gas mixtures by sparks from 2-MHz and 9-MHz sources[ J]. Radio and Electronic Engineer, 1981,51 (4) : 170 - 174.
  • 7James R A, Excell P S, Keller A Z. Probabilistic factors in radio-frequency ignition and detonation hazards analyses [J].Reliability Engineering, 1987,17 ( 2 ) : 139-153.
  • 8丁伯良.动物中毒病理学 [M].北京:中国农业出版社,1996.207.
  • 9Hultberg B, Andersson A, Isaksson A. Alterations of thiolmetabolism in human cell lines induced by low amounts of copper,mercury or cadmium ions[J]. Toxicology, 1998, 126(3): 203- 212.
  • 10Secombes C J, Fletcher T C. The role of phagocytes in the protective mechanism of fish[J]. Annual Rev of Fish Diseases, 1992, 53- 72.

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部