期刊文献+

流动注射分光光度法测定环境水样中镉 被引量:5

Determination of Cadmium in the Water by Flow Injection Spectrophotometry
下载PDF
导出
摘要 建立了镉-氨水.氯化铵缓冲溶液-对偶氮苯重氮氨基偶氮磺酸-甲醛高灵敏度显色体系下,采用流动注射技术测定环境水样中镉的方法,优化了试验条件,讨论了共存离子与色度的影响及消除办法。方法在6.00μg/L^460μg/L范围内线性良好,检出限为0.1μg/L,实际水样测定的加标回收率为98.6%~102%。 A method with high sensitivity system of Cd -NH3·NH4Cl -ADAAS was established to detercadmium in water by flow injection. The test conditions were optimized and the influence of eoexistions with color as well as its removal were discussed. The good linear relation of the method was obtained in range from 6. 00 μg/L to 460 μg/L. The detection limit was 0. 1 μg/L,recoveries of practical samples 98.6% - 102%.
出处 《环境监测管理与技术》 北大核心 2008年第5期33-35,共3页 The Administration and Technique of Environmental Monitoring
关键词 流动注射 分光光度法 水质 Cadmium Flow injeetion Spectrophotometry Water quality
  • 相关文献

参考文献4

  • 1马建中,陈新江,刘凌云.表面活性剂与高新技术制革[J].皮革科学与工程,2002,12(5):27-32. 被引量:8
  • 2BOEVSKI I,DASKALOVAU N,HAVEZON I. Determination of barium, chromium, cadmium, manganese, lead and zinc in atmospheric particulate matter by inductively coupled plasma atomic emission/spectronmetry ICP-AES[ J ]. Spectrochimi Acta B, 2000 (55) :1643 - 1657.
  • 3KARUNASAGAR D, ARUNACHALAM J. Determination of cadmium by inductively coupled plasma mass spectrometry-reduction of molybdenum oxide interferences by addition of aectonitrile [ J]. Anal,2001(441 ) :291 - 296.
  • 4王贤奕,赵云,洪陵成.水中Cr(Ⅵ)的流动注射在线监测[J].环境监测管理与技术,2007,19(2):39-40. 被引量:6

二级参考文献11

共引文献12

同被引文献70

引证文献5

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部