现阶段我国大多数石化企业中大量使用国产离心泵产品,存在运行效率低的问题。本文对100AYⅢ-120ⅹ2B离心泵在分支管路系统进行现场测试,得到多组试验数据,并对试验数据进行分析,最终确定合理节能改造方案。
At this stage, the majority of China's petrochemical enterprises use large domestic centrifugal pumps products, and there all exist problem of low efficiency. In this paper,test of 100 AYⅢ - 120× 2B centrifugal pump is carried out on branch pipeline system. In the on- site testing, by obtaining and analysing test data, the rational energy- saving reform programme is determined.
出处
《节能技术》
CAS
2008年第5期468-470,共3页
Energy Conservation Technology
关键词
离心泵
节能
叶轮
centrifugal pump
energy - conservation
impeller