基于DSP和ARM的电能质量监测系统 被引量:9

Power quality monitoring system based on DSP and ARM
下载PDF
导出
摘要 本文根据IEC和国家标准,主要针对我国电力行业面临的现状提出了一套基于DSP+ARM的电能质量监测系统。利用DSP高速的运算和处理能力实现对采集到的数据进行处理和计算;应用ARM模块高性能、外围接口丰富等特性实现对处理后电能参数的储存和用户的远程通讯等功能。本文讨论了本方案与其他设计方案的区别,提出了本方案的优点,最后的运行结果也表明所设计的监测系统能够长期稳定运行于电网的工业环境,并且能够满足各项指标的要求。 According to the IEC and national standards, we have proposed an monitoring system of power quality based on DSP and ARM,mainly aimed at the actuality in face of our national electric power industry. While utilizing the highspeed operation and processing ability of DSP, it can implement a processing and computation progress of the data which was gathered, and making use of some characteristics of ARM module, such as its high performance and ample periphery interfaces, it can carry out the storage of power parameter after processing, or fulfil the function of tekecommunications with customers. Here discussed the difference between our scheme and other design proposal, presented the advantage of our scheme, and the result of experiment has shown that our monitoring system can run steadily in the industry environment of Power Grid, at the same time, it can meet the requirement of all targets.
出处 《电子测量技术》 2008年第10期64-67,共4页 Electronic Measurement Technology
关键词 电能质量 DSP ARM power quality DSP ARM
  • 相关文献

参考文献7

二级参考文献31

  • 1毛晓波,吕建明.电力参数的交流采样技术及软硬件设计研究[J].仪器仪表学报,2001,22(z1):195-196. 被引量:32
  • 2李亮,阙沛文,陈亮.新型霍尔传感器在电流检测中的应用[J].仪表技术与传感器,2005(4):3-4. 被引量:32
  • 3王瑞敏,邓瑞清.电力线路谐波测量仪的研究[J].电网技术,1995,19(2):40-42. 被引量:3
  • 4董其国.电能质量技术问答[M].北京:中国电力出版社,2003..
  • 5吕润余.电力系统高次谐波[M].中国电力出版社,1998..
  • 6Realtek Semiconductor Corporation.RTL8019AS DOC[EB/OL].[2004-03-17].http://www.realtek.com.tw
  • 7爱赛德无线电小组.GSM模块使用文档[EB/OL].[2004-05-03].http://www.ascend-tech.com
  • 8Cypress Semiconductor Coporation.SL811HS Embedded USB Host/Slave controller[EB/OL].[2004-07-11].http://www.21ic.com
  • 9Mack Grady W,Surya Santoso.Understanding power system harmonics[J].IEEE Power Engineering Review,20001,21(11):8-11.
  • 10Ananth I,Morcos M M.A power quality monitoring system:a case study in DSP-based solutions for electric power industry[J].IEEE Power Engineering Review,1999,19(7):47-50.