摘要
针对现行标准和验收规范中,保温层塑料锚栓抗拉承载力现场试验方法和结果评定不明确,导致塑料锚栓拉拔试验报告只有检测数据而没有是否合格的检测结果判定问题,从相关标准和规范方面展开分析,并就有关问题进行讨论,提出了相应建议。
No clear in its result evaluation within determine its result validity site testing the current This paper method of strain resistant of plastic anchor and bolt used in heat preservation layer and standard and acceptant code, lead to the test report only have tested data but can't to analysis and discuss the problems in current standard and acceptant code and proposed suggestion.
出处
《工程质量》
2008年第11期43-45,共3页
Construction Quality
关键词
保温层
塑料锚栓
抗拉承载力
现场检验
heat preservation layer
plastic anchor and bolt
strain resistant
on site test