摘要
对101例脑血管疾病患者^(99m)TcECD SPECT脑血流灌注显像结果进行分析并与X—CT显像进行比较。101例中,男83例,女18例。脑梗塞69例,脑出血18例,TIA6例,椎动脉供血不足8例。其中78例有X—CT显像结果。结果:脑血流灌注显像阳性率88%,其中脑梗塞94%,脑出血94%,TIA50%,椎动脉供血不足50%。脑血流灌注显像异常表现呈多样性。有缺血灶病例占37%,灌注减少82%,过度灌注30%,15%的病例出现CCD现象。X—CT显像阳性率78%,同样的病例脑血流灌注显像阳性达94%。结论:SPECT脑血流显像对脑血管疾病脑血流的研究有较大价值,其各种显像异常表现的临床价值有待深入研究。
Objective:The results of the cerebral blood flow imaging of cerebrovascular disease wereanalysed and compared with that of X-CT. Method: ^(99m)Tc-ECD SPECT was used to image the cerebralblood flow in 101 CVD patients including cerebral infarction, cerebral hemorrhage, TIA and vertebralbasal artery insufficiency(VBI). Results: The positive rate of SPECT was 88% and that of X-CT was78% respectively .The abnormal rCBF images varied from ischaemia to hyperperfusion. 37% cases haveischemic lesions, 82% decreased lesions, 30% hyperperfusion and 15% CCD. Conclusions: rCBF SPECTimaging is useful to study the rCBF change of patient with CVD .The clinical values of diffrent abnormalperfusion lesions should be studied more.
关键词
脑血流
脑血管病
断层摄影术
SPECT
Cerebral blood flow
Cerebrovascular disease
Tomography
Emission computed
Single photon