摘要
分析了上海地区混凝土预制桩断桩的主要原因、对单桩承载力的影响,介绍了检测断桩的办法和判别处理方法。
The main reasons of precast concrete pile broken in Shanghai area as well as the effect of single pile bearing capacity are analyzed, the methods of assessment and teatment of broken-pile are also introduced.
出处
《上海建设科技》
1997年第5期23-24,26,共3页
Shanghai Construction Science & Technology
关键词
混凝土预制桩
断桩
单桩承载力
桩基测试
上海
precast concrete pile broken—pile dynamic experiment stastic experiment single pile bearing capacity.