摘要
采用Diamond C18不锈钢柱[150mm×4.6mm(i.d.),5μm]和二极管阵列检测器,以甲醇-水混合溶剂(80:20,v/v)为流动相,流速1.0mL/min、检测波长310nm和柱温35aC,建立了茚虫威制剂10%悬浮剂的高效液相色谱分析方法。茚虫威在0.5-10mg/L的浓度范围内,其峰面积(Y)与质量浓度(x)呈现良好的相关性,其线性回归方程为y=23372x+3238.2,R2=0.9993。在10%悬浮剂中,茚虫威5个添加浓度水平的平均回收率为99.29%,相对标准偏差(RSD)为1.05%,说明所建立的方法快速、灵敏度高、重现性好,可用于茚虫威10%悬浮剂产品质量控制与分析。
A quantitative high performance liquid chromatography method using diode array detector has been developed for the determination of the active ingredient indoxaearb in the formulation 10% suspension concentrate (SC). A diamond C18 stainless steel column [150 mm×4.6 mm (i.d.), 5 μm] was used with mixture of methanol-water (80:20,v/v)as the mobile phase at a flow rate of 1.0 mL/min,the column temperature 35℃ and the ultraviolet detection wavelength 284 nm. There existed good linear correlation between peak area (y) and concentration (x) of indoxacarb in the concentration range of 0.5-10 mg/L with the regression equation y=23 372x +3 238.2,R2=0.999 3. The average recovery of the five spiked levels for indoxacarb 10% SC was 99.29% , relative standard deviation 1.05% and coefficient of variation 0.01%,suggesting that the method should be fast,sensitive,reproducible and practical for the quality control and analysis of indoxacarb 10%SC during the manufacture of the product.
出处
《精细化工中间体》
CAS
2008年第5期62-64,共3页
Fine Chemical Intermediates
关键词
茚虫威
悬浮剂
液相色谱
indoxacarb
suspension concentrate (SC)
HPLC