应用CFX对堆芯围桶开孔处温度场及流场进行模拟计算并对结果进行分析。利用模型Ⅰ、Ⅱ分别计算得到堆芯围桶开孔处的温度场及流场,并得到在正常工况下堆芯围桶开孔处钠的流动方向。计算验证了事故余热排出系统(CAPX)水台架的试验结果,为CEFR堆芯围桶开孔的安全分析打下基础。
The paper gives analysis of the temperature and flow field around openings by software CFX, and figures out the flow direction around openings under CEFR normal condition. The calculation result is consistent with the test result of CAPX (the test-bed of decay heat removal system) and ground for the safety analysis later.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
2008年第10期916-919,共4页
Atomic Energy Science and Technology
关键词
中国实验快堆
堆芯围桶
流场
温度场
China Experiment Fast Reactor
core barrel
flow field
temperature field