摘要
火力发电厂经常存在许多疏水、冷却水、保护水在设计和投产初期不能够及时回收,造成高品质水白白浪费。针对吉林油田热电厂机组的调门冷却水及抽汽逆止门保护水流失情况进行研究,通过采取三级水封原理对这部分高品质水进行回收。
Much sparse water,cooling water and pre- served water can't be recycled in time at the initial stage of design and operation in the thermal power plant,thus high-qualitly water is wasted in the process.The essay researches on the protection of water loss of The Thermal power plant of Jilin Oil Field Using Valve cooling water and extraction check valve,recycling this high-quality water by applying three-level water seal theory.
出处
《石油化工安全环保技术》
CAS
2008年第5期63-64,共2页
Petrochemical Safety and Environmental Protection Technology
关键词
疏水
冷却水
保护水
回收
水封原理
Sparse water
Cooling water
Preserved water
Recycling
Water seal theory