分析了CKD7F型机车柴油机起机后冷却水的温度较低而冷却风扇却开始惰转的原因。针对故障原因实施了改进,使问题得到解决。
The reason of the fault that the cooling fan began idling at lower cooling water temperature when the diesel engine just started.By adopting the corresponding countermeasures,the fault was eliminated.
出处
《内燃机车》
北大核心
2008年第11期18-19,共2页
Diesel Locomotives
关键词
CKD7F型机车
静液压系统
管路
气动截止阀
CKD7F diesel locomotive
cooling fan
hydrostatic system
piping
pneumatic out-off valve