期刊文献+

双源CT双能量肺灌注成像的初步观察 被引量:50

Initial study of dual energy lung perfusion imaging using duni-source CT
原文传递
导出
摘要 目的评价双源CT双能量扫描肺灌注成像的临床应用价值。方法选择2007年5月至8月临床怀疑肺部疾病的连续54例患者行肺部增强双能量扫描,按照肺部不同病变分为4组:正常组、渗出性病变组、肿块性病变组和肺栓塞组。分析不同组别之间双能量CT灌注成像的表现。结果正常组14例,肺部双能量灌注成像表现双侧肺部灌注对称,未见明显差异。渗出性病变组10例,表现为局部灌注量降低;肿块性病变组27例,因为发生位置不同肺部灌注成像表现各异,外周性肿块表现为局部肿块区域的灌注缺损,而中央型肿块因为累及肺门血管而表现为肺段性灌注降低区或缺损区。肺栓塞组3例,表现为肺栓塞区域的灌注缺损或稀疏。结论利用双源CT双能量扫描可以观察肺的灌注状态,尤其有利于评价中央型肺癌和肺栓塞患者肺灌注的异常。 Objective To evaluate the clinical values of dual energy lung perfusion using dualsource CT. Methods Fifty-four patients who underwent chest contrast-enhanced CT were included in this study from May to August in 2007. Dual energy CT scanning was performed in all patients. The patients were divided into four groups: normal group, exudation lesion group, mass lesion group, and pulmonary embolism group. Imaging appearances of dual energy CT perfusion in four groups were analyzed. Results Dual energy CT showed symmetrical homogeneous perfusion in healthy subjects (n = 14), exudation lesions (n = 10) appeared as low perfusion, In mass lesions (n =27), peripheral masses presented as local perfusion defect, central masses appeared as segmental perfusion defect because of the involvement of hilar vessels, and pulmonary embolism (n = 3 ) appeared as perfusion defect in corresponding pulmonary segment. Conclusion Dual energy CT scanning can be used to show the pulmonary perfusion status and assess the pulmonary perfusion abnormalities in central lung cancer and pulmonary embolism.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2008年第11期1183-1186,共4页 Chinese Journal of Radiology
关键词 体层摄影术 X线计算机 灌流 诊断显像 Lung Tomography,X-ray computed Perfusion Diagnostic imaging
  • 相关文献

参考文献10

  • 1Johnson TR, Nikolaou K, Wintersperger BJ, et al. Dual-source CT cardiac imaging: initial experience. Eur Radiol, 2006, 16: 1409-1415.
  • 2Leber AW, Johnson T, Becker A, et al. Diagnostic accuracy of dual-source multi-slice CT coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J,2007, 28:2354-2360.
  • 3Matt D, Scheffel H, Leschka S, et al. Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. A JR,2007,189:567-573.
  • 4Johnson TR, Krauss B, Sedlmair M, et al. Material differenfation by dual energy CT: initial experience. Eur Radiol, 2007, 17: 1510-1517.
  • 5Primak AN, Fletcher JG, Vrtiska TJ, et al Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol,2007,14 : 1441-1447.
  • 6张龙江,卢光明.双源CT及其临床应用[J].中华放射学杂志,2008,42(2):206-208. 被引量:65
  • 7李蓓蕾,陈绍亮.核素肺通气/灌注显像在肺动脉血栓栓塞症中的应用[J].中华核医学杂志,2006,26(6):339-342. 被引量:11
  • 8Ohno Y, Hatabu H, Murase K, et al. Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: preliminary experience in 40 subjects. J Magn Reson Imaging,2004,20:353-365.
  • 9Groell R, Peichel KH, Uggowitzer MM, et al. Computed tomography densitometry of the lung: a method to assess perfusion defects in acute pulmonary embolism. Eur J Radiol, 1999,32: 192-196.
  • 10Wildberger JE, Niethammer MU, Klotz E, et al. Multi-slice CT for visualization of pulmonary embolism using perfusion weighted color maps. Rofo,2001,173 :289-294.

二级参考文献34

  • 1Flohr TG, Schoepf UJ, Ohnesorge BM. Chasing the heart: new developments for cardiac CT. J Thorac Imaging,2007,22:4-16.
  • 2Flohr TG, MeCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006,16:256-268.
  • 3Ohnesorge BM, Flohr TG, Becker CR, et al. Multi-slice and dual-source CT in cardiac imaging: principles, protocols, indications, and outlook. 2nd ed. Berlin : Springer-Verlag, 2007, 327-358.
  • 4Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol, 2006,16:2739-2747.
  • 5McCollough CH,Primak AN ,Saba O,et al. Dose performance of a 64-ehannel dual-source CT scanner. Radiology, 2007, 243 : 775-784.
  • 6Achenbach S, Ropers D, Kuettner A, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience. Eur J Radiol, 2006,57:331-335.
  • 7Schoepf UJ, Zwemer PL, Savino G, et al. Coronary CT angiography. Radiology,2007,244:48-63.
  • 8Lescohka S, Scheffel H, Desbiolles L, et al. Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol, 2007,42:543-549.
  • 9Matt D, Scheffel H, Leschka S, et al Dual-source CT coronary angiagraphy: image quality, mean heart rate, and heart rate variability. AJR ,2007,189:567-573.
  • 10Husmann L, Leschka S, Desbiolles L, et al. Coronary artery motion and cardiac phases : dependency on heart rate :implications for CT image reconstruction. Radiology, 2007, 245 : 567-576.

共引文献74

同被引文献1939

引证文献50

二级引证文献461

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部