摘要
结合标准规范及检测工作实践,探讨了钢筋保护层的重要性,阐述了钢筋混凝土结构的主要技术特点及钢筋保护层厚度的确定,分析了钢筋保护层质量问题的产生原因及控制方法,以便更好地解决钢筋保护层的质量问题。
Combined with standard specifications and practices the importance of cover to reinforcement is discussed as well as the major technical characteristics of RC structure and the determination of the thickness of cover to reinforcement. Reasons caused the quality problems of cover to reinforcement are analyzed, at the same time corresponding control methods are proposed in order to well deal with those quality defects of cover to reinforcement.
出处
《山西建筑》
2008年第34期224-225,共2页
Shanxi Architecture
关键词
结构实体
钢筋保护层
混凝土抗压强度
抗拉强度
悬挑构件
structural concrete, cover to reinforcement, compression strength, tensile strength, cantilevered member