期刊文献+

汽轮发电机3次谐波电压随负荷变动的理论分析 被引量:4

Theoretical Analysis of the 3rd Harmonic Voltage of Turbo-generator with Load Changes
下载PDF
导出
摘要 大型汽轮发电机机端3次谐波电压U3t以及中性点3次谐波电压U3n随有功负荷和无功负荷变动而变化,根本原因是定子绕组3次谐波电压EΦ3受负荷影响,从而影响到3次谐波电压的100%定子接地保护。通过磁导分析法以及傅里叶级数,推导了汽轮发电机转子磁动势和定子电枢反应磁动势产生的EΦ3,通过分析有功和无功负荷变动情况下发电机的磁动势、电势相量,得到了有功和无功对EΦ3的影响关系。分析表明,转子q轴方向上的小齿易饱和是影响EΦ3的重要原因,中性点接地设备参数的非线性可能是导致U3t/U3n发生变化的一个原因。 While active and reactive power change, the 3rd harmonic voltages at the terminals (U3t) and at the neutral (U3n) of large-sized turbo-generator also change. The basic reason is that the load change causes the 3rd harmonic voltage changing of stator windings (Eφ3), so that the 100% stator ground fault protection based on the 3rd harmonic voltage will be influenced. By magnetic field analysis method and Fourier series, Eφ3, which is generated by field magnetomotive force (MMF) and armature MMF, is studied. By studying the MMF and electromotive force (EMF) phasors while active or reactive power changes, the influence relationship of the active or reactive power change to Eφ3 is obtained. The analysis results indicate that it is an important factor to affect Eφ3, due to the saturation of the rotor teeth at q axis. And it may be a reason of U3t/U3n changing that the parameters of the neutral grounding device are non-linear.
出处 《电力系统自动化》 EI CSCD 北大核心 2008年第21期61-64,共4页 Automation of Electric Power Systems
关键词 汽轮发电机 3次谐波电压 定子接地保护 电枢反应 磁导分析法 turbo-generator the 3rd harmonic voltage stator ground fault protection armature reaction magnetic field analysis method
  • 相关文献

参考文献5

  • 1艾德胜.三次谐波式定子接地保护若干问题的探索[J].江苏电机工程,1985,(2):9-21.
  • 2段乃娴.国产20万千瓦汽轮发电机三次谐波电压实测与分析[J].电力系统自动化,1987,11(3):18-25,11.
  • 3FULCZYK M. Voltage 3rd harmonic in generator stator winding at changes in generator load conditions//Proceedings of IEEE International Electric Machines and Drives Conference: Vol 3, June 1-4, 2003, Madison, WI, USA: 1476-1482.
  • 4李玉海,张小庆,徐敏.关于定子接地保护的几个问题[J].电力系统自动化,1999,23(11):50-54. 被引量:24
  • 5王毓东 罗荣杰 郑元耀.汽轮发电机谐波励磁的分析[J].浙江大学学报,1978,(1):91-116.

二级参考文献12

  • 1李玉海,王洪超.三次谐波式定子接地保护几个问题的探讨[J].电力自动化设备,1993,13(1):22-28. 被引量:2
  • 2马肃,李玉海.JDJ──31型三次谐波式定于接地保护存在问题的研究及改进[J].电力自动化设备,1994,14(2):27-30. 被引量:2
  • 3王维俭.发电机变压器继电保护应用[M].中国电力出版社,1997,12..
  • 4李玉海 龚振华.叠加直流式定子接地保护存在的问题及对策[J].电力自动化设备,1987,(1).
  • 5艾德胜.发电机定子绕组100%接地保护方案的比较[J].电力自动化设备,1985,(1).
  • 6张军政,电力自动化设备,1997年,2期
  • 7王维俭,发电机变压器继电保护应用,1997年
  • 8马肃,电力自动化设备,1994年,2期
  • 9李玉海,电力自动化设备,1993年,1期
  • 10李玉海,电力自动化设备,1987年,1期