摘要 气体绝缘开关设备(GIS)中发生局部放电(以下简称局放)时,为查找绝缘缺陷,需对局放源进行准确定位。超高频(UHF)时差定位法由于原理简单、实现方便、定位精度高等优点获得了广泛应用,但当局放信号的初始脉冲较小而难以确定信号的起始脉冲时间时,UHF时差法将难以有效运用从而导致较大误差。为提高时差定位法的准确性,对局放电磁波在GIS中的传播路径特性进行研究,分析结果表明,局部放电产生的电磁波在GIS中的传播路径与局放源的位置、检测点的位置密切相关,据此提出了基于传播路径的脉冲时差定位法。实验结果表明,当局放源位于GIS外壳附近、电磁波信号初始脉冲很小、难以辨识时,用该方法可以准确定位。 It's necessary to accurately locate the partial discharge (PD) source to find the insulation defect when PD happens in the gas insulated switchgear (GIS). The ultra-high frequency (UHF) based time of flight method is widely used for its merits such as simple principle, easy implementation, and high location acc^lracy. But if the initial pulse of the PD signal is small and blurry, the time of flight method can hardly be applied effectively but will induce rather big errors. To improve the precision of location, the propagation route characteristics of electromagnetic waves excited by PD in GIS are investigated. It is shown that the electromagneticwave propagation route is closely related to the site of PD source and the position of the detector. A PD location method based on the characteristics of the electromagnetic wave propagation route is proposed. Experimental results show that the locating method is precise and effective when the PD source is near the shell of GIS and the initial pulse of the PD signal is very small and hardly distinguishable from background noise.
出处 《电力系统自动化》 EI CSCD 北大核心 2008年第21期77-81,共5页 Automation of Electric Power Systems
关键词 气体绝缘开关设备(GIS) 局部放电 电磁波 传播路径 时差法 定位 gas insulated switchgear (GIS) partial discharge electromagnetic wave propagation route time of flight method location
  • 相关文献

参考文献13

二级参考文献48

共引文献339

同被引文献293

引证文献41

二级引证文献501

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部