期刊文献+

HPLC-MS/MS快速同时测定全血中3种免疫抑制剂的浓度 被引量:6

Simultaneous and Rapid Determination of Three Immunosuppressants in Human Blood by HPLC/MS/MS
下载PDF
导出
摘要 目的建立液质联用(HPLC—MS/MS)法同时测定人全血中环孢素A、他充莫司、西罗莫司的方法。方法采用Symmetry C18色谱柱(2.1mm×50mm,5μm),流动相:10mmol·l^-1醋酸铵-0.1%甲酸溶液和0.1%甲酸甲醇溶液为90:10,流速0.25mL·min^-1,采用多反应监测进行定量.结果环孢素A在人全血中50~1500μg·L^-1。内线性良好,他克莫司、西罗莫司在人全血中1~30μg·L^-1内线性良好,相对回收率在98.67%~103.56%之间,日内及日间精密度(PSD%)均小于10%。结论本方法能满足同时测定人全血中环孢素A、他克莫司、西罗莫司的要求,用于临床血药浓度的监测。 OBJECTIVE To develop a HPLC/MS/MS method for simuhanenus determination of cyelosporin A, tacrolimus and sirolimus in human blood. METHODS The separation was performed on a Symmetry C18 (2. 1 mm × 150 mm,5 μm) column with a mobile phase of water (containing 10 mmol· L^-1 ammonium acetate and 0. 1% formic acid) and methanol (containing 0. 1% formic acid). Multi-reaction monitoring mode was employed for the quantitative determination. RESULTS The standard curve of cyclosporine was linear over the range of 50 - 1 500 μg · L^-1. The standard curves of tacrolimus and sirolimus were linear over the range of 1 - 30 μg · L^-1 , the relative recovel7 was among the range of 98.67% - 103.56% , RSDs of intraand inter-day validation were less than 10%. CONCLUSION HPLC-MS/MS can be nsed for the simultaneous determination of cyclosporin, tacrolimus and sirulimus in human blood.
出处 《中国药学杂志》 CAS CSCD 北大核心 2008年第21期1643-1647,共5页 Chinese Pharmaceutical Journal
关键词 免抑制剂 环孢素A 他克莫司 西罗莫司 高效液相色谱-质谱/质谱 血药浓度 immunosuppressant cyclosporine lacrolimus siroliruns HPLC/MS/MS concentration
  • 相关文献

参考文献5

  • 1HARDMAN J G, LIMBIRD L E. Goodman & Gilman'S Pharmacological Basis of Therapeutics(古德曼·吉德曼 治疗学的药理学基础) [M]. Tenth Edition Beljing: People's medical publishing House, 2002:1339.
  • 2VICENTE F B, SMITH F A, PENG Y,et al. Evaluatian of an immunoassay of whole blood sirolimus in pediatric transplant patients in comparison with high-performance liquid chromatugraphy/tandem mass spectrometry [ J ]. Clin Chem Lab Med, 2006,44 ( 4 ) :497 -499.
  • 3BORROWS R, CHUSNEY G, LOUCAIDOU M, et al. Tacrolimus monitoring in renal transplantation: a comparison between high- performance liquid chromatography and immunoassay [ J ] .Transplant Proc,2005,37(4) :1733-1735.
  • 4SALM P, TAYLOR P J, LYNCH S V, et al. A rapid HPLC-mass spectrometry cyclosporln method suitable for current monitoring practices [ J ]. Clin Biochem,2005,38 ( 7 ) :667-673.
  • 5RAYMOND G M. Immunosuppressant drag monitoring: is the labortary meeting clinical expections? [ J ]. Transplantation ,2005, 39(1) :119-127.

同被引文献75

引证文献6

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部