期刊文献+

微型称量滴定法测定工业循环冷却水的总硬度 被引量:2

Micro weight titration for determining the total hardness of industrial circulating cooling water
下载PDF
导出
摘要 以自制的液滴质量为0.005~0.010 g的聚乙烯塑料毛细滴管以及电子天平代替普通称量滴定装置进行微型滴定,不仅简化了实验装置,缩短了水样预处理时间,减少了试剂用量,而且减轻了热胀冷缩、量器误差和人为操作等因素带来的不利影响,使测定过程更方便、快速,从而建立了一种易于推广和应用的毛细滴管-电子天平微型称量滴定分析新方法。采用该法测定工业循环冷却水的总硬度,当滴定剂用量为0.5 g左右时,加标回收率为98.8%~101.2%,RSD为0.48%~1.14%,值得推广应用。 The micro weight titration by using polyethylene plastic capillary burette whose weight is 0.005-0.010 decrease the disadvantageous influences, such as the change caused by temperature, errors caused by measuring vessels and operators'visual observation. On the other hand, this technique makes the determining course more quick and convenient. Above all, a new titration analytical method which is much easier to be generalized and applied has been established. The method is used for determining the total hardness of industrial circulating cooling water. When the titration reagent is about 0.5 g, the indexed recovery rate will be 98.8%-101.2%, and the RSD will be 0.48%-1.14%. Therefore, it is worth being popularized.
作者 蔡成翔
出处 《工业水处理》 CAS CSCD 北大核心 2008年第11期65-68,共4页 Industrial Water Treatment
基金 广西教育厅科研项目(200707MS085)
关键词 微型称量滴定法 毛细滴管 总硬度 工业循环冷却水 micro weight titration capillary titration burette total hardness industrial circulating cooling water
  • 相关文献

参考文献7

二级参考文献9

  • 1JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 2杭州大学化学系分析化学教研室.分析化学手册(第2分册)[M].北京:化学工业出版社,1982.331-333.
  • 3GB 7477—1987,水质钙和镁总量的测定EDTA滴定法[S].
  • 4GB 12593-1990,工作基准试剂(容量)乙二胺四乙酸二钠[S].
  • 5GB/T 601-2002,化学试剂标准溶液的制备[S].
  • 6JJG 196-1990,国家计量检定规程常用玻璃量器[S].
  • 7GB 12593-1990.工作基准试剂(容量) 乙二胺四乙酸二钠[S],1990.
  • 8刘文明,马卫兴,钱保华.络黑T光度法测定水的硬度[J].理化检验(化学分册),2000,36(9):426-427. 被引量:9
  • 9罗明辉,杨勤,韦永勤,饶恒.定量化学分析实验微型化的研究[J].化工高等教育,2002,19(3):71-72. 被引量:15

共引文献70

同被引文献6

引证文献2

二级引证文献3