期刊文献+

PET—MRI:值得期待的分子影像未来 被引量:4

PET-MRI : the likely future of molecular imaging
原文传递
导出
摘要 PET—CT实现了功能和解剖结构显像的融合,在临床和科研中均获得了巨大成功。MRI是另一种解剖显像方法,与CT相比它具有更好的软组织对比度和空间分辨率,如果能实现PET和MRI的同机融合,将可能对分子影像学产生更深远的影响。主要综述目前PET-MRI研制存在的问题和进展情况,并展望其潜在的临床和科研价值。 PET-CT is a successful combination of functional and morphologic information, and it has already been shown to have great value both in clinics and in scientific research. MRI is another kind of morphologic imaging method, in contrast to CT, MRI can yield images with higher soft-tissue contrast and better spatial resolution. The combination of PET and MRI for simultaneous data acquisition should have farreaching consequences for molecular imaging. This review will talk about the problems met in the development of PET-MRI and describe the progress to date and look forward to its potential application.
出处 《国际放射医学核医学杂志》 2008年第4期196-201,共6页 International Journal of Radiation Medicine and Nuclear Medicine
关键词 体层摄影术 发射型计算机 磁共振成像 图像处理 计算机辅助 Tomography, emission-computed Magnetic resonance imaging Image processing,compute-assisted
  • 相关文献

参考文献23

  • 1Raylman RR, Hammer BE, Christensen NL. Combined MRI-PET scanner: a Monte Carlo evaluation of the improvements in PET resolution due to the effects of a static homogeneous magnetic field [J]. IEEE Trans Nucl Sci, 1996, 43(4): 2406-2412.
  • 2Garlick PB, Marsden PK, Cave AC, et al. PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts [J]. NMR Biomed, 1997, 10(3): 138-142.
  • 3Shao Y, Cherry SR, Farahani K, et al. Simultaneous PET and MR imaging[J]. Phys Med Biol, 1997, 42(10): 1965-1970.
  • 4Mackewn JE, Strul D, Hallett WA, et al. Design and development of an MR compatible PET scanner for imaging small animals [J]. IEEE Trans Nuel Sei, 2005, 52(5): 1376-1380.
  • 5Shaw NR, Ansorge RE, Carpenter TA. Commissioning and testing of split coil MRI system for combined PET-MR[C]//International society for magnetic resonance in medicine, May 7-13, 2005, Miami Beach, FL, USA.
  • 6Pichler B, Lorenz E, Mirzoyan R, et al. Performance test of a LSOAPD PET module in a 9.4 Tesla magnet [C]//Conference Record of the 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference. Piscataway, NJ: IEEE, 1998: 1237-1239.
  • 7Pichler BJ, Pimpl W, Buttler W, et al. Integrated low-noise low- power fast charge-sensitive preamplifier for avalanche photodiodes in JFET-CMOS technology[J]. IEEE Trans Nucl Sci, 2001, 48(6): 2370-2374.
  • 8Pichler B J, Judenhofer MS, Catana C, et al. Performance test of an LSO-APD detector in a 7-T MRI scanner for simuhaneous PETMRI[J]. J Nucl Med, 2006, 47(4): 639-647.
  • 9Judenhofer MS, Catana C, Swarm BK, et al. PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet[J]. Radiology, 2007, 244(3): 807-814.
  • 10Grazioso R, Zhang N, Corbeil J, et al. APD-based PET detector for simultaneous PET/MR imaging[J]. Nucl Instrum Methods Phys Res A, 2006, 569 (2): 301-305.

二级参考文献7

  • 1Mürtz P, Krautmaeher C, Traber F, et al. Diffusion-weighted Whole-body MR Imaging with Background Body Signal Suppression:a Feasibility Study at 3.0 Tesla[J]. Eur Radiol, 2007,24- 29.
  • 2Moon WJ, Lee MH,Chung EC. Diffusion-weighted Imaging with Sensitivity Encoding (SENSE) for Detecting Cranial Bone Marrow Metastases: Comparison with T1-weighted Images [J]. Korean J Radiol,2007,8(3) :185-191.
  • 3Lain WW,Poon WS,Metreweli C. Diffusion MR Imaging in Glioma:Does it Have any Role in the Pre-operation Determination of Grading of Glioma [J]. Clin Radiol,2002,57(2) :219-221.
  • 4Koh DM,Collins DJ. Diffusion-weighted MRI in the Body: Applications and Challenges in Oneology[J]. AJR,2007,188(6) :1622- 1635.
  • 5Takahara T,Imai Y,Yamashita T,et al.Diffusion Weighted whole Body Imaging with Background Body Signal Suppression(DWIBS):Technical Improvement Using Free Breathing,STIR and High Resolution 3D Display[J].Radiat Med,2004,22(4):275-282.
  • 6Nael K, Fenehel M, Krishnam M, et al. High-spatial-resolution Whole-body MR Angiography with High-acceleration Parallel Acquisition and 32-channel 3.0-T Unit: Initial Experienee[J]. Radiology, 2007,242(3) :865-272.
  • 7Nael K, Fenchel M, Krishnam M, et al. High-spatial-resolution whole-body MR Angiography with High-acceleration Parallel Acquisition and 32-channel 3.0-T Unit: Initial Experience[J]. Radiology, 2007,242 (3) : 865-272.