摘要 以聚偏氟乙烯(PVDF)为敏感材料,石英晶体微天平(QCM)为敏感元件构成聚合物QCM传感器。该文主要对神经毒剂模拟剂DMMP的气敏特性进行研究,并重点讨论了温度对PVDF聚合物膜层QCM传感器性能的影响。结果表明,当测试温度愈接近PVDF的玻璃化温度,传感器的响应幅值就愈高,且在各个DMMP测试气氛浓度时,传感器的响应幅值对温度的依赖性均符合Arrhenius关系;升高温度有利于提高传感器的响应速度,但同时其灵敏度却降低。 Poly (vinylidene fluoride) (PVDF) modified quartz crystal microbalance (QCM) sensor has been prepared for DMMP vapor detection. The temperature influence on the performances of the sensor was emphatically investigated. The results show that the sensitivity of the sensor is higher with the working temperature closer to the glass transition temperature (Tg) of PVDF, and the absolute frequency responses of the PVDF coated QCM sensor all exhibit negative Arrhenius temperature dependency in spite of different vapor concentrations. In this case, increasing the sensor operating temperature resulted in an improved response time while worse sensor sensitivity was also observed.
出处 《电子科技大学学报》 EI CAS CSCD 北大核心 2008年第6期934-937,共4页 Journal of University of Electronic Science and Technology of China
基金 国家杰出青年基金(60425101) 国家自然科学基金重点项目(60736005)
关键词 Arrhenius关系 聚偏氟乙烯 QCM传感器 温度 Arrhenius dependency poly(vinylidene fluoride) QCM sensor temperature
  • 相关文献

参考文献12

  • 1VIVEROS L, PALIWAL S, Mccrae D, et al. A fluorescencebased biosensor for the detection of organophosphate pesticides and chemical warfare agents[J]. Sensors and Actuators B, 2006, 115: 150-157.
  • 2徐秀明,王俊德,李海洋.QCM和SAW传感器的原理及其在现场检测中的应用[J].化学进展,2005,17(5):876-880. 被引量:12
  • 3杨秋冬,谢海芬,孙晓翔,刘全,黄宜平.基于分子筛薄膜探测神经类毒气的传感器研究[J].传感器与微系统,2006,25(1):10-12. 被引量:3
  • 4刘卫卫,余建华,潘勇,赵建军,伍智仲,王艳武,黄启斌.声表面波技术检测糜烂性毒剂芥子气的研究[J].分析测试学报,2006,25(5):80-82. 被引量:2
  • 5CHOI S J, JIANG Z W. A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals[J]. Sensors and Actuators A, 2006, 128: 317-326.
  • 6WANG Shu-mci, WANG Zhan, ZHANG Yang, ct al. Expcrirncntal study of the control of pore sizes of porous membranes applying chemicals methods[J]. Desalination, 2005,177: 7-13.
  • 7DARGAHI J. A piezoelectric tactile sensor with three sensing elements for robotic, endoscopic and prosthetic applications[J]. Sensors and Actuators A, 2000, 80: 23-30.
  • 8NISHIOKA M, SADAKATA M, OKUBO T, et al. Gas sensing with zeolite-coated quartz crystal microbalances-principal component analysis approach[J]. Sensors and Actuators B, 2002, 86: 26-33.
  • 9LEVITSKY I, KRIVOSHLYKOV S G, GREAT J W. Rational design of a Nile red/polymer composite film for fluorescence sensing of organophosphonate vapors using hydrogen bhond acidic polymers [J]. Anal Chem, 2001, 73: 3441-3448.
  • 10MCGILL R A, ABRAHAM M H, GRATE J W. Choosing polymer coatings for chemical sensors[J]. Chemtech, 1994, 24: 27-37.

二级参考文献54

  • 1Massyoshi Sadakata,Tatsuya Okubo.Gas sensing with zeolite-coated quartz crystal microbalances-principal component analysis approach [J].Sensor and Actuator B,2002,86:26-33.
  • 2Xie Hai-fen,Yu Ting,Sun Xiao-xiang,et al.Gas sensor based on nano ZSM-5 zeolite films for the nerve agent simulant dimethylmethylphosphonate detection[J].SPIE,2005,5774:624-627.
  • 3Nakamoto T,Hiramatsu H.Study of odor recorder for dynamical change of odor using QCM sensors and neural network [J].Sensor and Actuator B,2002,85:263-269.
  • 4Harris C M. Anal. Chem., 2003, 75(15): 355A-358A.
  • 5Herbert H H. Anal. Chem., 1997, 69: 289R-305R.
  • 6Wohltjen H, Dessy R. Anal. Chem. , 1979, 51 : 1458-1464.
  • 7Yinon J. Anal. Chem., 2003, 75(5): 99A-105A.
  • 8Ali Z. Journal of Thermal Analysis and Calorimetry, 1999, 55:397-412.
  • 9Marx K A. Biomacromolecules, 2003, 4:1099-1119.
  • 10O' Sullivan C K, Guilbault G G. Biosensors & Bioelectronics,1999, 14:663-670.

共引文献14

同被引文献13

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部